2.3 Setting up Hyper Terminal 1. Click [Start] – [All programs] – [Accesso ries] – [Communications] – [HyperTerminal]. 2. In the Connection Description dialog input “C onveyor” as shown in the following screen shot. 3. C…

3. Right click on [Communications Port (COM1)] and select [Properties]. Check that [Use
this device (enable)] is selected.
4. Click the [Port Settings] tab and check that the settings match those shown in the
following screen shot.
Check that [Use this device
(enable)] is selected
Check that the
settings are the
same as those
shown here
NXT Repair Training Textbook
Conveyor Unit
FK-9F98-43-0E
Edition 1.0 20 / 46 FUJI Machine Mfg. Co., Ltd.

2.3 Setting up Hyper Terminal
1. Click [Start] – [All programs] – [Accessories] – [Communications] – [HyperTerminal].
2. In the Connection Description dialog input “Conveyor” as shown in the following screen
shot.
3. Click [OK] and select [COM1] in the [Con
nect using] list box.
Input
Conveyor
here
Select
COM1
NXT Repair Training Textbook
Conveyor Unit
FK-9F98-43-0E
Edition 1.0 21 / 46 FUJI Machine Mfg. Co., Ltd.

4. Click [OK] and make the following settings in the COM1 Properties dialog:
5. On the HyperTerminal task bar select [File] – [Properties] and select the [Settings] tab.
Click [ASCII Setup…] and put check marks in the two check boxes indicated below:
6. Click [OK] to finish.
Make the
settings
shown here
Put check marks
in these two
check boxes
NXT Repair Training Textbook
Conveyor Unit
FK-9F98-43-0E
Edition 1.0 22 / 46 FUJI Machine Mfg. Co., Ltd.