ACT - Accuracy Check Tool.pdf - 第118页

ACT with SSW 7xx / User Manual 07/2017 Edition 10 NOTICE 1) Optional glass com ponents CC 07 - 500 The optional CC07 - 500 gl ass compone nts, item no. [00338000 - 02] were offered as option for measuring t he SST25 (FC …

100%1 / 220
ACT with SSW 7xx / User Manual 07/2017 Edition
9
NOTICE
The measuring plate and the special components have been specially designed for the
ACT.The measuring plate has global fiducials for PCB position recognition, fiducials for
component position measurement and a grid array, dot matrix (see Abbildung 1-2),
defined as inkspot in SIPLACE Pro.
In each glass component, 3 of 4 fiducials are integrated for measuring the component
position.
The special components used depend on the head or camera type fitted (see section
4.1).
2.3.1 Options / Spare Parts
Item description Item number Count
Glass component CC02-005 (single) 00338002-01 Glass component (single)
Glass component CC07-500 (single) 00338000-02 Optional glass component (single)
1)
Cerampads 2x2 mm in blister tape (for use in
dust-free rooms)
03116117-01 Reel with 2 500 components
Base ACT magazine, complete 03069924-01 Empty magazine (tray) without cover
Cover for ACT magazine, complete 03069888-01 Cover for ACT magazine (tray)
Cover for glass plate, complete 03056782-01 Cover for glass plate (Calibration Board)
Light plate 03056307-01 Plate on the underside of the glass plate
Knurled screw DIN 464 M4 x 16 03031104-01 For closing the glass plate
Knurled screw DIN 464 M4 x 12 03031103-01 For closing the magazine (tray)
Recommended additional parts:
Nozzle type 1204 cpl. ceramic 03154095-01 Ceramic nozzles for ACT C&P20A head
Nozzle magazine type 10xx (CP20a, CP20M) 03016831-05 Magazine for 12 nozzles C&P20A (1xxx)
Nozzle type 2204 cpl. ceramic 03153518-01 Ceramic nozzles for ACT C&P20 P head
Nozzle magazine type 20xx (CPP) 03066107-02 Magazine for 12x nozzles CPP
Nozzle type 4204/6204 cpl. ceramic 03149000-xx Ceramic nozzles for ACT C&P20 P head
Nozzle magazine type 40xx (CP20p, CP20M2) 03101503-01 Magazine for 20 nozzles C&P20 P
Tray in Conveyor for ACT Option
Consists of:
See Chapter 5
Tray glass1, complete 03058749-01 Empty tray with space for 117 glass
components of size 18x18 mm
Cover for tray AVS, complete 03063446-01 Cover for tray mentioned above
Knurled screw DIN 464 M4 x 12 03031103-01 For closing the magazine (tray)
Long adapter (4 knurled screws included) 03056010S01 For connecting tray and glass plate (for single
lane conveyor)
Table 2-3: Options / Spare parts
ACT with SSW 7xx / User Manual 07/2017 Edition
10
NOTICE
1)
Optional glass components CC07-500
The optional CC07-500 glass components, item no. [00338000-02] were offered as
option for measuring the SST25 (FC camera) up to station software version 707.1.
As of station software version 707.1 and SIPLACE Pro 11.x, this component is not
supported anymore.
Instead, a component description CC02-05_FC is available in SIPLACE Pro as of
version 11.x.
ACT with SSW 7xx / User Manual 07/2017 Edition
11
2.3.2 Individual Components in the ACT Set
Measuring plate (glass plate) in metal frame (Figure 2-1 and Figure 2-2):
The glass components and the measuring plate are kept in a storage case.
Figure 2-1: Storage case for measuring plate Figure 2-2: Storage case for glass components
The glass components used for ACT are placed in the milled divisions in the waffle pack tray
(Abbildung 2-3).
Figure 2-3: Waffle pack tray for glass components
Key:
(1) Waffle pack tray
(2) Waffle pack tray carrier
(3) Glass components