ACT with SSW 7xx / User Manual 07/2017 Edition
63
4.2.5.3 Saving the Report under Station Software 703.xx and Higher
► Click the Save results button (
see Figure 4-35).
The report will be saved in PDF format.
The first time you save a report, you must specify a path in which the pdf file shall be stored.
(Example: C:\ACT\Reports)
Up to SW 707.1, the file name for the report is made up as follows:
As of SW 707.1, the file name for the report is made up as follows:
Key:
(1) Machine type (4) Time
(2) MID (5) Measured lane
(3) Date (6) Camera type / Sensor system type
Figure 4-37: Accuracy Check Report

ACT with SSW 7xx / User Manual 07/2017 Edition
64
4.2.6 Finishing the ACT – Returning to Production
4.2.6.1 Finishing (e.g. under Station Software 70x)
► Click the Schließen (Close) button in the measurement results view to close it.
Figure 4-38: Closing measurement results view
► Load the board into the output section (1).
Figure 4-39: Loading board into the output section
► Click on the button to the left at the bottom (2) to return to the main view of the GUI.

ACT with SSW 7xx / User Manual 07/2017 Edition
65
In the station main view you will now see the board highlighted in red in the output section,
from where you can remove it.
► Remove the board from the output section.
► If it is not possible to remove the board, because it is a machine of the SX- or DX-series that is
positioned in the middle of a line of several machines, then click on the red board.
Figure 4-40: State after ACT
► In the next window, select the Cancel board option.
► Select the sub-function Remove from last station of the line.
► Click OK to confirm.
Figure 4-41: Removing board from the last station of the line
► Press Start.
The board is unloaded from the station.