ACT - Accuracy Check Tool.pdf - 第145页

ACT with SSW 7xx / User Manual 07/2017 Edition 37 4.1.2.3 Accessibility P roblems for Various M achine / H ead Configurations SIPLACE SX4 and DX4 machines: NOTICE In order to access the fiducials, t he ACT measuring pl a…

100%1 / 220
ACT with SSW 7xx / User Manual 07/2017 Edition
36
4.1.2.2 Specifying ACT Programs in Stand Alone Mode
Due to the above-described permanent storage of the placement programs on the station, a once-
defined program can be repeated at any time in stand-alone mode at the station, without having to
re-specify via SIPLACE Pro.
You are in the Stand alone mode (1).
Figure 4-4: Stand alone mode
Select a new board (placement program) from the stored list on the station under New board
(2).
The boards stored on the station are listed in the following window.
Figure 4-5: Permanent specification
The permanently stored boards are marked with a Padlock symbol (1).
Mark the corresponding line.
Either specify the board on one lane (2) or on both lanes simultaneously (3).
ACT with SSW 7xx / User Manual 07/2017 Edition
37
4.1.2.3 Accessibility Problems for Various Machine / Head Configurations
SIPLACE SX4 and DX4 machines:
NOTICE
In order to access the fiducials, the ACT measuring plate has to be placed rotated by
180° in SIPLACE SX4 and DX4 machines.
Thus, if an ACT placement program is defined for a SIPLACE SX4 or DX4 machine, the orientation
(position) of the board has to be adapted to 180° in the created recipe.
Figure 4-6: Rotating board orientation by 180° on SX4, DX4
If this adaption of the board orientation is not performed, the following error message (example) is
already displayed on the SIPLACE Pro Line Control GUI during specification:
Figure 4-7: Example: Error message due to unavailable ink spots
NOTICE
Due to the problems of accessing the fiducials described above, please observe:
If the ACT has to be measured on a machine of the SX-, DX-, or X-series, in front of
which one or more SIPLACE SX4- or DX4-stations are arranged in a line, the Pass-
through function has to be activated on all machines in front of the measuring machine
that require another board orientation (0°/180°).
ACT with SSW 7xx / User Manual 07/2017 Edition
38
Twin Head in Placement Area 1:
For machines with Twin Head in placement area 1 (i.e. gantry 1 and / or 4), you can use the
following adapter to ensure the accessibility of segment 2 during placement on the plate. The
adapter is placed on the front of the plate to move the plate by a total of 50 mm to the rear in the
direction of the input belt.
50 mm TWIN adapter [03085310-01]
Figure 4-8: 50 mm TWIN adapter
If you use the "50 mm TWIN adapter" [03085310-01] in the outmost panel, you must extend the
board by 50 mm in SIPLACE Pro Desk!
For this, enter 390 mm length instead of 340 mm in the board description that you want to use
(ACT_CC02-05_CPP_TH).
Figure 4-9: Extending the board