ACT - Accuracy Check Tool.pdf - 第169页

ACT with SSW 7xx / User Manual 07/2017 Edition 61 Errors Displays the numbe r of measurement errors per mea surement. The use r decides whether the number of errors i s too high and whet her to repeat the measurement pro…

100%1 / 220
ACT with SSW 7xx / User Manual 07/2017 Edition
60
NOTICE
When measuring the ceramic components, the placement angle cannot be calculated, as
the ceramic components are too small to deliver reliable information for the angle.
Therefore the angle is not displayed.
For the CA-series and X-series S micron machines with C&P20 M placement heads and
the corresponding programs with "High Precision" flag, the expected measurement
accuracy is so high that the errors occurred due to the component size are irrelevant for
the result.
The measured values are highlighted in color. This allows you to see, for instance, whether
components which were positioned with a particular placement angle and by a particular segment
show particularly significant deviations.
The PDF evaluation (see section 4.2.5.3) outputs data on segments and overall values for the Twin
Head.
NOTICE
In rare cases (pickup errors and thereafter recovery placement), individual segment
assignments might not be correct. If it is necessary to know the segment assignments
when analyzing the measurement results, the placement has to be repeated until the
segment assignments are correct.
The results displayed in the Statistics area and the graphical view of the measurement results
match the selected head and the selected segment.
Mean (calculated average, offset)
The average calculated here relates to the results activated in the head selection (and for Twin
Head, segment selection). This is the calculated average, i.e. the sum of all measured values /
number of values.
Median (central value)
The median relates to the results activated in the head selection, too (and for Twin Head, segment
selection). This is the "middle one" of the measuring values. To determine the median, all
measuring values are arranged according to size. The measuring value in the middle of the list of
all measuring values then shows the median (by 5 measuring values this is the 3rd value).If there is
an even number of measurement values, the median is defined to be the arithmetic mean of the
two middle values (by 4 measuring values (x2 + x3) / 2). The median is inured to so-called runaway
values, because these will be sorted at the beginning or the end of the list of measuring values.
Standard deviation
The standard deviation is displayed as 4
σ
or as 3
σ
(for CA, micron, E by SIPLACE).
Automatic Offset Correction…
The offset data can be automatically corrected. A click on the appropriate button opens a dialog in
which the offset values to be corrected (median values) can be selected. See section 4.2.5.2.
Measured values
Displays the total number of measurements.
ACT with SSW 7xx / User Manual 07/2017 Edition
61
Errors
Displays the number of measurement errors per measurement. The user decides whether the
number of errors is too high and whether to repeat the measurement process.
Check the measuring plate before you repeat the measurement. Possibly the foil was not
applied to the plate without air bubbles or the surface is scratched or dirty if the plate has been
used several times.
Repeat measurement
Repeats the current measurement in the selected mode, another placement operation will not be
performed. Each measurement can only be stored once (Report created). If the measurement is
repeated it can be stored again (Create report).
ACT with SSW 7xx / User Manual 07/2017 Edition
62
4.2.5.2 Correcting the Measured Offsets
Click the Automatic offset correction button (
see Figure 4-35).
The following dialog box is opened:
Figure 4-36: Correction of the measured offset values (median)
Key:
(1) Clicking on a line highlights it in blue. Clicking on the same line again cancels the
highlighting. To select multiple lines, click them while holding down the (Ctrl) key.
(2) Here you can customize the view, e.g. hide individual columns.
(3) Transfers all selected offset values to the machine data.
(4) This transfers all offset values to the machine data whether they are selected or not.
The corrected values are active immediately after having been stored.
Terminate the current measurement and assemble and measure the plate again.
NOTICE
If you are using a dual conveyor and want to run the ACT with the next conveyor lane, all
you need to do is insert the glass plate into the input conveyor of the current lane once
the components have been removed. This triggers the ACT. You do not need to select a
new mode for the measurement.
NOTICE
The transparent foil, with adhesive on both sides, can be used multiple times.