ACT - Accuracy Check Tool.pdf - 第160页

ACT with SSW 7xx / User Manual 07/2017 Edition 52 NOTICE ► Check the orientat ion of the inserted pla te if you see the f ollowing error me ssage (ACT cross cannot be measured). Figure 4-24: Error message c aused by faul…

100%1 / 220
ACT with SSW 7xx / User Manual 07/2017 Edition
51
4.2.3 Inserting the Plate
Insert the glass plate with the incident light plate (black metal plate) underneath it in the input
section.
NOTICE
The measuring plate needs to be inserted so that the arrows marked on the plate show
in the transport direction.
Figure 4-22: Placing the measuring plate in the conveyor (example SIPLACE X4)
CAUTION
Caution for SX4 and DX4 machines:
The measuring plate needs to be inserted so that the arrows marked on the plate show
against the transport direction on the SX4 and DX4 machines.
Figure 4-23: Placing the measuring plate in the SX4 / DX4 conveyor with the calibration structure (ink spot forward)
ACT with SSW 7xx / User Manual 07/2017 Edition
52
NOTICE
Check the orientation of the inserted plate if you see the following error message
(ACT cross cannot be measured).
Figure 4-24: Error message caused by faultily inserted plate; example SW 705
ACT with SSW 7xx / User Manual 07/2017 Edition
53
4.2.4 Loading the Plate into the Measuring Machine
4.2.4.1 X-Series
On the SIPLACE X-series machines the glass plate can be inserted into the conveyor by opening
the covers of the input section (extension kit) or the machine cover.
Insert the plate directly into the input section of the measuring machine so that the sensor is
activated.
Press Start.
The board is automatically moved into the placement area and gets placed.
Thereafter, the measurement is automatically started, see section 4.2.5.
Figure 4-25 and Figure 4-26 show an assembled ACT plate, in one example with glass
components and in the other with ceramic components.
Figure 4-25: Measuring plate with placed glass comp. Figure 4-26: Measuring plate with placed ceramic comp.
4.2.4.2 SX-Series and DX-Series
On the SIPLACE SX- and DX-series machines the reachability to insert the plate in the input
section is limited, particularly on machines that are placed in the middle or at the end of a line.
Therefore, the plate has to be inserted at the first machine of the line.
Press Start.
Insert the plate up to 50%+x into the input section of the first machine.
Click on the Conveyor interface button directly under the conveyor in the station software
(see Figure 4-27).
Figure 4-27: Conveyor interface button