9 C&P Placement Heads 9.4.2 Z Axis Up 9.4 Travel Profiles - Placement Student Guide SIPLACE D-Series (FSE) 171 Benefits of special mode "waiting time - placement" With the "waiting time - pl acement&qu…

100%1 / 290
9 C&P Placement Heads
9.4 Travel Profiles - Placement 9.4.1 Z Axis Down
170 Student Guide SIPLACE D-Series (FSE)
9.4.1.3
9.4.1.3 Placement: Z Axis Upwards "Creep to Target Position"
Placement: Z Axis Upwards "Creep to Target Position"
Benefits of the Special Mode "Creep to Target Position"
The "slow approach to placement height" option allows you to:
FLIP-CHIP components with their ball-type leads can be dipped into the filler material on the board
without trapping any air!
However, this option makes the placement procedure around 20 ms longer than the standard place-
ment procedure!
9.4.1.4
9.4.1.4 Detailed Placement Procedure: Z-Axis Downwards with Waiting Time at Placement
Detailed Placement Procedure: Z-Axis Downwards with Waiting Time at Placement
Detailed component placement procedure: Z axis up
-
wards with slow approach to placement height
In the case of LRU/LRL 503 and SIPLACE Pro, this
placement type can "only" be programmed in the CS "for
SR/MC 503 stations and higher".
End position signal for X/Y and star axes:
All 3 end position signals available
Perform vacuum test "before placement", to deter-
mine whether the component is at the nozzle.
Z axis starts:
Positioning of Z axis downwards, the selected speed
profile switches over to minimum speed 1 mm before
reaching the placement height.
LB up switches:
Electromagnetic valve for air blast ON
Enable signal for "light barrier down" function
LB down switches:
End signal Z axis positioning downwards;
And valve positioning drive pickup/placement position
ON for air blast
Detailed component placement procedure: Z-Axis down
-
wards with waiting time at placement
End position signal for X/Y and star axes:
All 3 end position signals available
Perform vacuum test "before placement", to deter-
mine whether the component is at the nozzle.
Z-axis starts:
Positioning of Z-axis downwards
LB up switches:
Electromagnetic valve for air blast ON
Release signal for function LB down
LB down switches:
End position signal for positioning Z-axis down;
And valve positioning drive pickup/placement posi-
tion ON for air blast
Special mode "Waiting time down"
The end position signal Z-axis down starts the waiting
period timer in the MC.
After the waiting period, the air blast pressure is
measured.
Positioning upwards begins.
9 C&P Placement Heads
9.4.2 Z Axis Up 9.4 Travel Profiles - Placement
Student Guide SIPLACE D-Series (FSE) 171
Benefits of special mode "waiting time - placement"
With the "waiting time - placement" option you can:
Combine any of the Z-axis operating modes.
With this "waiting time - placement" option you can:
Press the BARE-DIE component into the adhesive with placement force, so that the adhesive flows
under the component surface and sticks over the surface.
Very big COs can be pressed into the soldering paste so that all leads contact with the paste.
9.4.2
9.4.2 Z Axis Up
Z Axis Up
9.4.2.1
9.4.2.1 Standard Mode - Placement: Z-Axis Up
Standard Mode - Placement: Z-Axis Up
CAUTION
The Z-axis moves up (SW 6xx) if the emergency stop button is pressed or a protective cover is
opened!
NOTICE
The pickup process offers the same programming options for a waiting period at the bottom (for
pickup from surftape feeders (typical: 250 ms)). However, due to the waiting period, this option
makes the placement procedure longer than the standard placement procedure!
Detailed component placement procedure: Z-axis up
LB down switches:
End position signal for downwards and valve posi-
tioning drive "ON" for air blast
Measurement of air blast pressure during placement
Start signal for upwards movement
Z-axis starts:
Positioning of Z-axis upwards
LB up switches:
Electromagnetic valve for air blast OFF
Reset LB down signal
Start signal for gantry axes
Z-axis end position signal (Z-axis at 0 position):
Enables vacuum query: "Segment airtight" after
placement (SR/MC503)
Start signal for star axis
Legend
1. End position signal for Y-axis (position to next place-
ment position)
2. End position signal for star axis
3. Uncommutated motor current for Z-axis
4. End signal Z-Axix – Teh secondsignal is displayed
with a time delay of ca. 25 ms
9 C&P Placement Heads
9.5 Settings 9.5.1 Boards at C&P12
172 Student Guide SIPLACE D-Series (FSE)
9.4.2.2
9.4.2.2 Placement: Z-Axis Upwards with "Slow Start"
Placement: Z-Axis Upwards with "Slow Start"
Benefits of Special Mode "Slow Start"
Das BE bleibt sicher auf der LP liegen, auch wenn die Haftkräfte der Lotpaste sehr gering sind.
9.5
9.5 Settings
Settings
9.5.1
9.5.1 Boards at C&P12
Boards at C&P12
All the settings described in this chapter are head-specific and apply here for the C&P12.
9.5.1.1
9.5.1.1 8-fold DIP Switch of the gantry head distributor (incl. switch S1) C&P6/12
8-fold DIP Switch of the gantry head distributor (incl. switch S1) – C&P6/12
Detailed component placement procedure: Z-axis up
-
wards with slow start from placed component
From LRU/LRL 503 and SIPLACE Pro, this placement
type can "only" be programmed in the CS "for SR/MC 503
stations and higher".
LB down switches:
End position signal for downwards and valve posi-
tioning drive ON for air blast
Measurement of air blast pressure during placement
Start signal for upwards movement
Z-axis starts:
Positioning Z-axis up with reduced starting speed for
the first 44 digits
LB up switches:
Electromagnetic valve for air blast OFF
Reset LB down signal
Start signal for gantry axes
Z-axis end position signal (Z-axis at 0 position):
Enables vacuum query: "segment airtight?" after
placement (SR/MC503)
Start signal for star axis
NOTICE
However, this option makes the placement procedure around 20 ms longer than the standard
placement procedure.
DIP switch Switch position Designation
1 OFF P0 (see below)
2 OFF P1 (see below)
3 OFF "S1" for test mode (see below)
4 OFF BL – Enable boot loader for serial port
5 OFF Res (Reset) – CAN processor 16 bit (TQ module)
6 OFF C0 – no current function
7 OFF C1 – no current function
8 OFF S2 – switch for DLM head (no current function)