00195440-05-SG_D-Series_FSE-EN.pdf - 第83页
5 Energy and Compressed Air Supply 5.2.3 Input Voltage 5.2 Power Supply Unit Student Guide SIPLACE D-Series (FSE) 83 5.2.3 5 . 2 . 3 I n p u t V o lt a g e Input Voltage Input voltage Legend 5.2.4 5 . 2 . 4 N a m in g C …

5 Energy and Compressed Air Supply
5.2 Power Supply Unit 5.2.2 Overview of Power Supply
82 Student Guide SIPLACE D-Series (FSE)
Main power supply – front view (D4/D4i)
Legend
1. F1: 3x 230 V AC
SZ1: main contactor
MS1: Motor protection switch
S1: main switch
2. F2: 220 V AC for 5 V power supply
F4: 3x 140 VAC X/Y axes
SZ2,SZ3, SZ23: auxiliary contactors U,V,W for X/Y
servos
3. F5: 150 V DC star axis servo
F6: 40 V DC Z/DP axis servo
F7: 40 V DC changeover table
F8: 40 V DC PCB handling (conveyor)
F9: 8 V DC changeover table (only at D4/D4i)
F10: 48 V DC Vision illumination
F11: 24 V DC terminal strip distributor 2/4
F12: 24 V DC Microbox PC (MC)/control "ON" (K1)
F13: 24 V DC Box PC (SR)/axis unit 1/2
F14: 24 V DC conveyor control (TSP 301)/monitors
Z2: discharge inductor
4. K1: protective contactor combination
Relay1: control ON - button
SZ4: control ON - software
FU: fuse 6.3 AT 220 VAC to GND
FV: fuse 6.3 AT 220 VAC to GND
FW: fuse 6.3 AT 220 VAC to GND
FBU: fuse 6.3 AT 220 VAC to GND
X1: feed in - terminal strip
BU1: service socket

5 Energy and Compressed Air Supply
5.2.3 Input Voltage 5.2 Power Supply Unit
Student Guide SIPLACE D-Series (FSE) 83
5.2.3
5.2.3 Input Voltage
Input Voltage
Input voltage
Legend
5.2.4
5.2.4 Naming Convention of Connectors and Cables
Naming Convention of Connectors and Cables
The SIPLACE basic machine cables and leads are clearly labeled. Each cable, connector, distributor
uses an exact term, which is dedicated to the sections and units in question.
S1 Main switch F1 Fuse for 24 V power pack
MS1 Motor protection switch F2 Fuse for 5 V power pack
SZ1 Main contactor and inrush current limiter
Machine type: D1/D2/D3/D4/
D1i/D2i/D4i
--/D2/--/D4/-/
D2i/-/D4i
--/--/D3/D4/
--/-/D4i
--/--/D3/D4/
--/--/D4i
Placement head for Gantry 1 Gantry 2 Gantry 3 Gantry 4
Designation a+ b+ c+ d+
Trailing cable distributor 03035887 aa ba ca da
Gantry distributor 03035888 ab bb cb db
Gantry head distributor 03038002 ac bc cc dc
Vision board eu fu gu hu
Hotlink filter lf mf nf of
SC Always pc
Hotlink card pr
MC Always pa
USB hub pd
Sector 1 af af af af
Sector 2 (output side) bf bf (left) bf bf

5 Energy and Compressed Air Supply
5.2 Power Supply Unit 5.2.5 Assemblies in Sector 1
84 Student Guide SIPLACE D-Series (FSE)
5.2.5
5.2.5 Assemblies in Sector 1
Assemblies in Sector 1
Sector 3 (output side) cf cf -- --
Sector 4 df df -- --
Subassemblies in the sector distributors have other designations, which may also differ between the
machine types.
Machine type: D1/D2/D3/D4/
D1i/D2i/D4i
--/D2/--/D4/-/
D2i/-/D4i
--/--/D3/D4/
--/-/D4i
--/--/D3/D4/
--/--/D4i
Placement head for Gantry 1 Gantry 2 Gantry 3 Gantry 4
Naming convention for cables and connections in sector
1
▪ Conveyor control ao (D1/D2/D1i/D2i: kc)
▪ Terminal strip (voltage supply) X100
▪ Connections (plug-in connectors) af
▪ Vision DC/DC converter A1 qc
▪ CAN Bus terminator for changeover table qd
In D1/D2/D1i/D2i, the subassemblies and the main dis-
tributor are marked with r...
The designations are as follows:
▪ A3 CAN bus terminator connection for changeover
table: rb
▪ A3 CAN bus terminator connection for WPC: rd
▪ Vision DC/DC converter assembly: rc
▪ The conveyor assembly TSP201 also has the con-
nector and lead designation ao.