4 Communication and Control
4.3 CAN Bus 4.3.4 Communication in SIPLACE D4/D4i
62 Student Guide SIPLACE D-Series (FSE)
4.3.4
4.3.4 Communication in SIPLACE D4/D4i
Communication in SIPLACE D4/D4i
Overview of communication in SIPLACE D4/D4i

4 Communication and Control
4.3.5 CAN Bus Terminating Resistors 4.3 CAN Bus
Student Guide SIPLACE D-Series (FSE) 63
4.3.5
4.3.5 CAN Bus Terminating Resistors
CAN Bus Terminating Resistors
Terminating resistors in D4/D4i machine – CAN Bus for one placement area
4.3.5.1
4.3.5.1 CAN Bus Terminator
CAN Bus Terminator
The A3 assembly ensures that the CAN bus also functions with undocked changeover tables. During
undocking, a CAN terminating resistor is switched, which maintains the CAN bus function and commu-
nication.
If the terminating resistance is measured with the machine switched off and the changeover tables con-
nected, you will be able to measure 30 Ohms at the Sub CAN bus (with 500kbit/s). Reason: There are
4x 120 Ohm resistors switched parallel. When the machine is switched on, the resistors switched in A3
will be deactivated.

4 Communication and Control
4.3 CAN Bus 4.3.5 CAN Bus Terminating Resistors
64 Student Guide SIPLACE D-Series (FSE)
There is an A3 assembly in each sector.
A3 assembly
CAN BUS terminator for changeover table (switch setting S1 on A3 assembly)
*1
D1/D1i/D2/D2i: WPC and sector 1
*2
D1/D1i/D2/D2i: Sector 2
COT Connections
.
A3 assembly
S
Feeder table
plate
Sector 1
*1
Feeder table
plate
Sector 2
*2
Feeder table
plate
Sector 3
Feeder table
plate
Sector 4
1ON OFFON OFF
2ON ON OFF OFF