5 Energy and Compressed Air Supply
5.3 Pneumatic System 5.3.3 Pneumatic Unit
90 Student Guide SIPLACE D-Series (FSE)
5.3.3
5.3.3 Pneumatic Unit
Pneumatic Unit
5.3.3.1
5.3.3.1 Overview of Pneumatic Unit
Overview of Pneumatic Unit
The pneumatic unit is a fixed installation inside the machine. The unit is accessible via a door and con-
tains the complete compressed air supply for all consumer devices.
Manometer Arrangement
Pneumatic unit as rack unit (D4/D4i)
Legend
1. Main compressed air connection with shutoff valve
and manometer
2. 4x connection for bulkcase feeder with manometer,
manually adjustable (2.5 bar), location 1-4
3. 4x connection for cutters, location 1 - 4
2x connection for conveyor lifting table
4. 4x connection for nozzle changer
5. 4x connection for docking/undocking the changeover
table
6. Electronic control valve for incoming pressure ma-
nometer.
7. 4x connection for gantries 1 - 4, vacuum generation
C&P head with shutoff valves
8. Compressed air filter (you may need a special tool to
open this)
NOTICE
Different pressure
Observe the different pressure for the nozzle changer on the D4/D4i machine (5.1 +/- 0.1 bar),
which is significantly higher than that for the nozzle changer of the D1/D2/D1i/D2i machines.
Main pneumatic unit: manometer arrangement (D4/D4i)
Legend
1. Manometer input pressure (5 – 10 bar)
2. Manometer regulated supply pressure 5.0 +0.1 bar
for placement heads
3. Manometer for reduced pressure 2.5 +/0.5 bar (man-
ually adjustable)
5 Energy and Compressed Air Supply
5.3.3 Pneumatic Unit 5.3 Pneumatic System
Student Guide SIPLACE D-Series (FSE) 91
Pneumatic Unit Manometer
Supply pressure
5.3.3.2
5.3.3.2 Compressed Air Distributor Block
Compressed Air Distributor Block
The pneumatic unit is used to prepare and distribute the compressed air required in the machine. The
pressure at the compressed air connection must be at least 5.5 bar.
The following pneumatic circuits are supplied with compressed air via the distributor block:
Overview of compressed air supply
Pneumatic unit (D1/D2/D1i/D2i)
Legend
1. Manual pressure regulator for setting the bulkcase
feeder pressure
2. Centronic flange – electronic pressure control valve
3. Compressed air filter
4. Pressure shutoff taps for gantry(ies)
5. Fixtures for pneumatic unit
6. Manometer – bulkcase feeder
7. Manometer – regulated pressure
Manometer /
Pos. No.
Target pressure Description
(6) 2.5 bar (+/- 0.5 bar)
(manually set)
For bulkcase, nozzle changer C&P6/12
(7) 5.1 (+/0.1 bar)
(electronically regulat-
ed)
For cutters, conveyor, changeover tables
For gantries (vacuum for C&P head and TWIN Head)
D4/D4i D3 D2/D2i D1/D1i
Gantries Vacuum gener-
ation Placement heads
5.1 +/-0.1 bar 4.5 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
Conveyor system 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
Tape cutter 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
Nozzle changer 5.1 +/-0.1 bar 2.5 +/-0.1 bar 2.5 +/-0.1 bar 2.5 +/-0.1 bar
Feed-in units 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar 5.1 +/-0.1 bar
Bulkcase feeder Manually set 2.5
bar
Manually set 2.5
bar
Manually set 2.5
bar
Manually set 2.5
bar
5 Energy and Compressed Air Supply
5.3 Pneumatic System 5.3.3 Pneumatic Unit
92 Student Guide SIPLACE D-Series (FSE)
5.3.3.3
5.3.3.3 Switch ON Sequence for Pneumatic Units
Switch ON Sequence for Pneumatic Units
Switch ON sequence for pneumatic units (example: D4/D4i)
The time for deactivation of the proportionate valve can be changed in the station software.
Settings
Configure compressed air
switch off after 1-60 minutes
5.3.3.4
5.3.3.4 Main Valve X89 for Regulation of Compressed Air
Main Valve X89 for Regulation of Compressed Air
After switching on the machine via the main switch, the valve is opened and compressed air flows into
the system. Opening covers, for example, has no effect on the air supply. However, if the 24 V voltage
supply fails or if the machine is switched off, the valve will close and the machine components will no
longer be supplied with compressed air. The valve is regulated via a pressure sensor. If the pressure
falls below 5.0 bar, the CAN bus will issue a signal.
NOTICE
Cause of Hazard
The proportional valve X89 is enabled as soon as the machine is switched on. After performing
the reference run, the proportionate valve X89 can be switched off via the software (2 minutes
as a default).
NOTICE
This main pressure regulator can be damaged if the machine is turned on without compressed
air supplied. Therefore if the compressed air supply fails, turn of the machine.