00195089-0102_AI_Vakuumpumpe_X-Serie_60X_DE+EN.pdf - 第108页
Assembly Instructions SIPLACE Vacuum Pump Ausgabe 07/2006 104 Fig. 2.10.3 Control connectors f or P or tals X1 through X4 2 Monitoring and/or control of the vacu um pump is available at the ea rliest starting with SW ver…

Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
103
Fig. 2.10.2 Open vacuum pump
(1) Factory-adjusted pressure limit valve
(2) Air filter
(3) Control connectors for 4 placement machines
2
: Fasten the vacuum hose (siphon and pressure hose) with a hose clamp.
: Trim the vacuum pump with a knife or wire cutter, based on your set-up.
: Secure the Y connector on the other end.
: Run one vacuum hose each to the individual placement machines.

Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
104
Fig. 2.10.3 Control connectors for Portals X1 through X4
2
Monitoring and/or control of the vacuum pump is available at the earliest starting with SW version
603.
If you would like to control the vacuum pump using the con
nected placement machine’s operating
state: 2
: Remove the strapping plug.
: Guide the control cable “cable power vacuum pump” (03049005-) through the opening below
the door.
: Plug in the control cables of each placement machine accordingly (X1 through X4).
: Plug the other ends into the plug X16 in the bottom distributor of each connected placement
machine (see Fig. 2.9.3).

Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
105
Fig. 2.10.4 Vacuum distributor block
: Secure the thick vacuum hose to the vacuum distributor block with a hose clamp.
2.10.1 Maintenance
For maintenance please follow the instructions in Chapter 9: Vacuum Pump Maintenance (Series
2SH, Type 2SH7 530) of the pump manufacturer’s operating instructions. 2
2
The operating instructions current at time of delivery are included with the vacuum pump. The
most current version of the operating instructions can be obtained using the SIPLACE DMS
system. 2