Assembly Instructions SIPLACE Vacuum Pump Ausgabe 07/2006 82

Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
81
: Connect the vacuum hoses with the vacuum distributor block (see Fig. 2.7.10).
: Seal the possibly still empty openings in the vacuum distributor block (with sealing plug
Q03051739-, plug QSC 16H).
: Seal the newly empty connections in the pneumatic unit with sealing plug QSC-12H.
2
: Do not close the shut-off valve. If you do, the necessary compressed air supply for the
placement and/or dropping cycle is interrupted.
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
82

Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
83
2.8 Portals
2
Retrofitting a distributor for placement heads for vacuum pump operation is shown below. 2
2