00195089-0102_AI_Vakuumpumpe_X-Serie_60X_DE+EN.pdf - 第69页
Assembly Instructions SIPLACE Vacuum Pump 2 Assembl y Instructions for Vacuum Pump SIPLACE X Series Ausgabe 07/2006 65 2 Assembly Instructions for V acuum Pump SIPLACE X Series 2.1 Functional description V acuum is neces…
Montageanleitung SIPLACE Vakuumpumpe
Ausgabe 07/2006
64

Assembly Instructions SIPLACE Vacuum Pump 2 Assembly Instructions for Vacuum Pump SIPLACE X Series
Ausgabe 07/2006
65
2 Assembly Instructions for Vacuum
Pump SIPLACE X Series
2.1 Functional description
Vacuum is necessary for all Collect&Place heads. So far the entire vacuum was produced using
Venturi jets in the Collect&Place placement head. 2
This vacuum pump produces vacuum more efficiently (then V
enturi jets) and thus lowers energy
usage. The base vacuum needs are hereby covered. 2
2
The Twin Head is not compatible with vacuum pumps. The pneumatic supply for a given portal
must not be converted to vacuum operation. If the compressed air supply for that head is
converted to vacuum operation, the return cylinder cannot extend and thus the z axis is stuck in
the top position. 2
2
If a portal is converted from Collect&Place to Twin Head, the original compressed air supply for
this portal must be reconstructed. All components for this portal must be reconstructed.
A partial conversion, e.g., of the pneumatic unit, can lead to severe failures in the placement
machine
when used in compressed air operation because the portal tubes (additional vacuum
tubes) can disconnect. 2
2
If a portal with Twin Head is converted to Collect&Place vacuum operation, the vacuum operation
for that portal must be retrofitted.
If a Collect&Place head which was converted to vacuum o
peration is operated at a compressed
air portal, the head could be severely damaged because the silicon tubes could disconnect. 2
2.2 Prerequisites
Prerequisites for retrofitting are: 2
a) Machines from series No. Š B-079 up with vacuum-cap
able cable drag chain: 2
– 03022236-01 cable drag chain for SIPLACE X series 1P
– 03022237-01 cable drag chain for SIPLACE X series 2P U
– 03021065-01 cable drag chain for SIPLACE X series 2P G
2
Retrofitting of placement machines from series lower than No. B079 is not possible. 2
2

2 Assembly Instructions for Vacuum Pump SIPLACE X Series Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
66
b) Placement head C&P20 Item no: 03008827-03 2
2.3 Necessary Parts
– Retrofit Kit Vacuum Pump Operation C&P20 Item no. 119790
– Retrofit Kit Vacuum Pump Operation X4 Item no. 119791
– Retrofit Kit Vacuum Pump Operation X3 Item no. 119792
– Retrofit Kit Vacuum Pump Operation X2 Item no. 119793
– Vacuum Pump X series 220V (3 ~ 400V) Item no. 119794
– Vacuum Pump X series 110V (3 ~ 208V) Item no. 119795
– Retrofit Kit Vacuum Pump Oper
ation C&P6/12
Item no. 119796
2.4 Necessary Tools
– flat wrench 10
– set of Allen wrenches
– set of Philips head screwdrivers
– wire cutter
– tube gripper
– release tool for Q8 Item no. 03047090-
2.5 Safety instructions
2.5.1 Safety Instructions for Vacuum Pump
In general, for the vacuum pump all manufacturer’s instructions – in addition to the safety
instructions in Paragraph 2.5.2 – regarding safety, particularly all
instructions regarding installation
and operation, must be followed. 2
When the vacuum pump type 2SH7 503 from Gardner Denver Elmo Technology GmbH is turned
on and off, it
can trip the ground leakage circuit breaker installed in the building's power supply.2
In that case Gardner Denver Elmo Technology recommends the use of a universal current-