Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
115
2.13 Technical Information
About Retrofitting for Vacuum Pump Operation
2.13.1 General Information About Vacuum Pump Operation
Mutual interference of multiple placement machines at a joint pump: 2
If multiple placement machines are connected to one vacuum p
ump, it is advisable to insert an
additional shut-off valve into the vacuum input before each placement machine. 2
2
2
During normal operation the vacuum in the vacuum distributor block at the machine input should
not fall below -500mbar. 2
2
To avoid any possible property damage despite this measure, the placement machines should not
be turned off if the vacuum pump is running. 2
2.13.2 Special Features of the C&P20 Placement Head
One vacuum pump can supply a maximum of 4 x C&P20 heads.
Example: 1x SIPLACE X4 with 4x C&P 20 o
r 2x SIPLACE X2 with 2x C&P 20 each 2
If the vacuum pump option is retrofitted, the Venturi vacu
um generator (“vacuum unit holding circle
C&P20") is replaced by the “orifice ring complete C&P20” (03046348-). Only the holding circle is
directly supplied by the vacuum pump. 2
In the collect and/or place position the pressure regulation
valve, as well as the return cylinder,
continue to be supplied with compressed air, independent from the holding circle. 2
The placement machine’s “vacuum usage” depends only on th
e number of placement heads and
the size of the pipettes. The more C&P20 heads are connected to the vacuum pump, the lower
the vacuum at the pipettes. 2
When starting placement operation the vacuum increases with each c
omponent picked up. A
median vacuum amount is quickly reached when pipettes are closed (components picked up) and
opened (components deposited) at the same time. 2
With an X4 during continuous placement operation, 2 of 4 heads are always closed by
component
s. 2
Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
116
2.13.3 Special Features of the C&P6/12 Placement Head
One vacuum pump can supply a maximum of 16 x C&P6/12 heads. 2
For the C&P6/12 a modified vacuum generator is inserted
at the C&P6/12 placement head. This
means the collection circuit is supplied by Venturi jets and the holding circle by the vacuum pump.2
If the placement head is in the waiting position, the star
is located between the two star positions
(half cycle). 2
In this intermediate position
the hold and collection circuits are connected via the grinder. If a
placement machine is turned off in this park position, the vacuum is lowered. This has
repercussions for the placement heads of all connected placement machines if no shut-off valves
have been inserted. 2
No interaction occurs among the placement machines conne
cted by the vacuum pump, even
without (closed) shut-off valves, only if the pipettes in the placement machine which is turned off
are in a vertical position. 2

Assembly Instructions SIPLACE Vacuum Pump
Ausgabe 07/2006
117
2.14 Final Work
2.14.1 Conditions for Turning the Machines on
2
Before turning the machines on, check the following to prevent injuries or major property damage:2
Before turning the compressed air back on, ensure that: 2
– all hose attachments and connectio
ns are co
rrectly allocated
(i.e. no compressed air flows into a vacuum hose)
–
all preconditions for turning on the vacuum pump and the placem
ent machines connected to it
have been followed as stated in the operating instructions.
– the vacuum pump is always turned on before the placement machine is turned on.
2
: Turn the vacuum pump on.
: If necessary, open the vacuum shut-off valves which have been inserted.
2
: Open the compressed air shut-off valve.
: Push the pneumatic unit into the placement machine.
: Close all doors.
: Turn on the main switch.
: Repeat above steps for all connected placement machines.