( 4.2.1 ) ( 4.2.2 )  Initial angle: d efault is 0°, if a ny spe cial ne ed, you can modify this a ngle to ch ange the compon ent’ s plac ement direction. Specia l attentio n for some chips with direction requirement, su…

100%1 / 52
5.2 Feeder setting
Select one feeder, tick “Apply”, then its related info can be edited such as feeder exchange, feeder, nozzle, IC tray feeder etc.
The setting sequence for them should be: Feeder (or IC tray feeder)→ Feeder basic information→ Nozzle.
P. S.: 1) For feeders 1-66, the IC tray feeder is in disabled condition. 2) Feeder exchange depends on application condition,
if the tape reel was installed on wrong feeder, you can directly use feeder exchange to solve it.
(1) IC tray feeder info
It is used to set tray package component’s pick position.
Right top XY: it refers to align the farthest component on the tray (generally take the component at right top as the
final one on the tray, and take the component at left bottom position as the first one)
X qty: it refers to how many components in X direction
Y qty: it refers to how many components in Y direction
Start X, Start Y: It refers to the first IC in X/Y direction if the tray is in full package; If some ICs have been used whic
h cause the tray is not full, you can directly set the exact position as actual situation, start X will be the location of its a
ctual column and start Y will be its actual location of row.
(2)Feeder basic info
Skip: once selected, all components in this feeder will be skipped.
Feeder exchange: this function can be used if any reel tape was installed at wrong or inappropriate position. Select
the feeder/ IC tray feeder you need to exchange, then the related feeder info will be synchronized to the swapped
feeder/ IC tray feeder.
Pick XY: Align the first component position in the feeder as fig.4.2.2, which is Mark camera align the component
central position, then click ”save and back”, the well-saved position’s X/Y coordinates will be automatically show up
as fig. 4.2.1 (P.S.: pick position can be set one by one or be set by the scale setting, scale setting is more convenient).
27
Zhejiang NeoDen Technology Co.,Ltd.
(4.2.1) (4.2.2)
Initial angle: default is 0°, if any special need, you can modify this angle to change the component’s placement
direction. Special attention for some chips with direction requirement, such as LED red/green, diode, IC etc.
Footprint/ Value: Component footprint/ value. Footprint refers to the footprint name like 0603, 0805, 1206 etc., Value
refers to component data like 10K, 75Ω etc.
Pick delay: For special components like large IC and large capacitor, it’s better to set some long time on the pick delay
to make sure nozzle can pick up them stably.
Place delay: For special components like large IC and large capacitor, it’s better to set some long time on the place
delay to make sure nozzle can still suck the component stably during the movement to place on the board.
Move speed: It is used to control the head movement speed, generally just keep default will be ok. It is need be
changed slower while doing some pick test.
Down speed: It is used to control the nozzle head Z-axis downward speed (Special notice: for lead pitch distance<
0.5mm, please set this to a lower speed).
Vision: Against component to choose applicable vision method. Such as:
For resistor/ capacitor--- please select Flying calibration
For component which do not require high precision --- you can also select No action
For IC --- you can select IC correction or big IC correction according to different IC sizes. The two methods difference
is: IC correction is one shot recognition; big IC correction is separately taking photos for IC’s four corners. So, if the IC size
more than 35mm, please directly select big IC correction method.
Accuracy: Generally normal resistor/ capacitor is default as high speed mode, do not need to modify it; For IC, please
select high accuracy mode.
Brightness: it refers to the brightness of component recognition (after be picked up) in assembly procedure.
28
Zhejiang NeoDen Technology Co.,Ltd.
29
Feeder type: Pneumatic and Electric two types for selection.
Nozzle: You can select single or several nozzle in different cases, once selected, they’ll be automatically assigned to
each feeder. Notice for edge position feeders, you can just use limited nozzle head to pick up components. If you’re not
sure, just click “Feeder Test ” button under the nozzle selection part. It will pop out below, you can test which nozzle is
available to pick up component from this selected feeder. Details for each button:
Select the nozzle head you need to test
Step pick test: the operation is, click this button after nozzle selected→ the nozzle head will move to this feeder→
feeder cover open → the nozzle down to pick up component → taking photo → throw component. This is sing step
operation, it can help the operator check if pick position/ pick height correct or not. If with problem, then can be re-set
in feeder basic setting.
Pick test: after nozzle selection, click this button, the head will move to feeder position and finish the pick up step
without any pause.
Recognition test: After the “Pick test” with component be picked up, then click this “Recognition test” to show the
Zhejiang NeoDen Technology Co.,Ltd.