3OM-1054-002.pdf - 第242页

0307-006 5-16 AGS01EDTP *12 X/Y table chute width [mm] This is the offset value indicating the difference between the chute width of the X/Y table and the actually measured value. (a) Measure the actual value at the P .C…

100%1 / 319
Plus parameters entered in these text boxes increase the
travel of the feeder carriages in the "Fdr. No." direction from
the component pickup position.
Fig. 3E15
*9 Feeder standby position
F1 [mm], F2 [mm]
Shown are the offset values (differences between the values of the feeder
standby position and the actually measured values of the feeder axis origin
position.
Fig. 3E15-1
*10 Input conveyor width [mm]
This is the offset value indicating the difference between P.C.B. Di-
mension Y and the actually measured conveyor width.
The actual value is measured after the conveyor width is
changed when the clearance data and device offset are re-
garded as “0” (zero).
*11 Output conveyor width [mm]
This is the offset value indicating the difference between P.C.B. Di-
mension Y and the actually measured conveyor width.
The actual value is measured after the conveyor width is
changed when the clearance data and device offset are re-
garded as “0” (zero).
0307-006 5-15
AGS01EDTP
3.2 "Device Offset" Tab
0307-006 5-16 AGS01EDTP
*12 X/Y table chute width [mm]
This is the offset value indicating the difference between the chute
width of the X/Y table and the actually measured value.
(a) Measure the actual value at the P.C.B. outlet/input sec-
tions (fixed sections). Do not perform the measure-
ment at the roller position of the slide block.
(b) The actual value should be measured after the con-
veyor width is changed when the clearance data and
device offset are regarded as “0” (zero).
*13 Support pin up/down [mm]
This is the offset value indicating the difference between the P.C.B.
thickness and the length of the support pin (actually measured value).
*14 Unit P.C.B. B.B.R.
X [mm], Y[mm]
This is the offset data used to correct the positional deviation of the
unit P.C.B. B.B.R. detection sensor.
X [mm] : Positional Correction Data in Horizontal Direction
Y [mm] : Positional Correction Data in Vertical Direction
3.2 "Device Offset" Tab
3.2.2 "Head" Tab
The "Head" tab sheet is composed of "Head Origin", "Head Offset", and
"Head Center Offset" tabs.
Sheet Layout
When the "Head" tab is pressed in the "Device Offset" tab sheet, the
following tab sheet appears.
Fig. 3E17
Sheet Composition
*1 [Head Origin] Tab
When selected, the "Head Origin" tab sheet appears.
*2 [Head Offset] Tab
When selected, the "Head Offset" tab sheet appears.
*3 [Head Center Offset] Tab
When selected, the "Head Center Offset" tab sheet appears.
0303-004 5-17
AGS01EDTP
*1
*2
*3
3.2 "Device Offset" Tab