3OM-1054-002.pdf - 第40页
(A01_12) Feeder No. offset Set an offset value as an offset of "Fdr No." in the placement feeder location. The placement feeder location data is shifted as much as the speci- fied value and the machine performs…

(A01_10) Feeder standby position
Set a "Fdr No." (feeder slot No.) as a feeder standby position.
000 : This function is disabled.
Entry of "Fdr No." : After a piece of P.C.B. is finished, the feeder
carriage returns to the specified feeder slot
No. (Fdr No. = Pick-Up Position).
Data Input Range : 101 to 159, 201 to 259
Any feeder slot No. (Fdr No.) which does not exist in the placement feeder
location data cannot be specified.
(A01_11) Alternate mode
Select one of the following options to determine whether or not the
alternate function should be used.
Disable : The alternate function is disabled.
Alternate Carriage : The unit alternate function is enabled.
Alternate Pallet : The pallet alternate function is enabled.
(a) The feeder alternate function can be specified in the placement feeder
location data.
(b) In TCM-X100J, the alternate pallet function is almost the same as
the alternate carriage one.
0303-005 2-20
AGS01EDTP
2.3 Operation Data
000
Feeder standby position
Fig. 3B26
Alternate mode
Fig. 3B27
Disable

(A01_12) Feeder No. offset
Set an offset value as an offset of "Fdr No." in the placement feeder
location.
The placement feeder location data is shifted as much as the speci-
fied value and the machine performs the pick-up operation.
Data Setting
±{{{
These two digits show the offset in increments of a
feeder location.
Data Input Range: 00 to 59
This digit shows the carriage No. to be shifted.
Data Input Range: 0 to 2
Fig. 3B29
(a) It is recommended that a value with a "+" (plus) sign should be en-
tered.
(b) Set "+000" not to use any offset.
(A01_13) X/Y table accel des
Select one of the following options to determine acceleration of the X/
Y table movement for component placement.
Full Speed 10%Decr 20%Decr 30%Decr
40%Decr 50%Decr 60%Decr 70%Decr
80%Decr 90%Decr
(a) In normal cases, select "Full Speed".
(b) When there are some previously-placed components, the transfer
speed can be decreased in advance to avoid component deviations
that may be caused by the X/Y table movement.
021 1-004 2-21 AGS01EDTP
2.3 Operation Data
+000
Feeder No. offset
Fig. 3B28
Full Speed
X/Y table accel des
Fig. 3B30

(A01_14) C1 accel des, C2 accel des
Select one of the following options to determine acceleration of each
feeder carriage movement for component picks.
Full Speed 10%Decr 20%Decr 30%Decr
40%Decr 50%Decr 60%Decr 70%Decr
80%Decr 90%Decr
(A01_15) Recovery regulation
U-N
When placement data is created to cope with the Un-specified multi-
model repetitive pattern function, the recovery regulation must be en-
abled.
Refer to "2.1 Types of P.C.B.’s and Required Data" for de-
tailed information on how to specify "Un".
Disable : The recovery regulation function is disabled.
The normal automatic recovery function is activated.
Enable : The recovery regulation function is enabled.
When the automatic recovery function is activated, a pat-
tern with the smallest "Un" No. is recovered first and the
subsequent patterns are recovered in the ascending or-
der.
As long as all components in the pattern (smaller Un No.)
are not recovered, no components are placed on the sub-
sequent Un No. (Unit).
01 12-003 2-22
AGS01EDTP
2.3 Operation Data
Fig. 3B32
U
-N
Block
Disable
Disable
C1 accel des
Fig. 3B31
Full Speed
C2 accel des
Full Speed