00196602-05_SM_SIPLACE_X-Feeder_EN.pdf - 第34页

6 Repairing the X Feeder modules 6.4 Tape Drive 34 Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017 6.4.2.4 Fitting the Splice Sensor (16 - 88 mm) ► (1) Insert the splice sensor connector through the opening in the tape…

100%1 / 90
6 Repairing the X Feeder modules
6.4 Tape Drive
Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017 33
6.4.2.3 Removing the Splice Sensor (16 - 88 mm)
► Remove the left side cover (see 6.3.1 "Removing the Left Side Cover" [}23]).
► Carefully place the feeder module down on its left side.
► Loosen the screw marked in the diagram.
► Remove the screw e.g. with a pair of tweezers.
► Insert the Phillips screwdriver through the marked
opening in the side cover.
► Loosen the back screw marked in the diagram.
► Remove the screw e.g. with a pair of tweezers.
► Carefully place the feeder module on its right
side.
► (1) Loosen the foam rubber which closes the
opening to the tape duct.
► (2) Unplug the splice sensor connector from the
connection on the board.
Use a small slotted screwdriver or similar tool to
help you.
Push the connector up and out of the connection
(see small diagram).
Do NOT pull on the cable.
► (3) Remove the splice sensor from the tape duct
and pull the cable and connector up and out of
the opening.
6 Repairing the X Feeder modules
6.4 Tape Drive
34 Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017
6.4.2.4 Fitting the Splice Sensor (16 - 88 mm)
► (1) Insert the splice sensor connector through the
opening in the tape duct.
► Make sure that the smooth side of the connector
is at the top.
► (2) Use a pair of tweezers or something similar to
carefully push the connector as far as the end
stop into the marked connection on the board.
 CAUTION!
Do not push the connector with force into the
connection, otherwise individual pins may break
off or be distorted.
.
 NOTICE!
Take great care when connecting the connector.
Take your time.
.
► (1) Position the splice sensor in the tape duct.
Gently tug on the splice sensor cable in the re-
cess on the feeder module side panel.
Make sure that none of the cable is in the tape
duct.
► (2) Run the cable as marked in the diagram.
► (3) Close the opening to the tape duct with the
foam rubber.
► Position the splice sensor in the tape duct.
► Hold the screw with a pair of tweezers in the rear
hole.
► Insert the Phillips screwdriver through the marked
opening in the side cover.
► Fasten the back screw marked in the diagram.
6 Repairing the X Feeder modules
6.4 Tape Drive
Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017 35
► Hold the screw with a pair of tweezers in the front
hole.
► Fasten the front screw marked in the diagram.
► Fit the left side cover into place (see section 6.3.2 "Fitting the Left Side Cover" [}24]).
6.4.3 Magnetic Shield (4mmX Only)
Required spare parts
Magnetic shield X4
Feeder module Item no. Designation
4 mm 03087341-Sxx Magnetic shield X4
Required tools
●
Phillips screwdriver
6.4.3.1 Removing the Magnetic Shield
► Remove the pickup window 6.4.1.1 "Removing
the Pickup Window (4 - 12 mm)" [}27]).
► Remove the two screws marked in the diagram.
Use a Phillips screwdriver for this.
► Remove the magnetic shield.