6 Repairing the X Feeder modules 6.7 Operating Panel Assembly Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017 77 ► Loosen the 2 screws marked in the diagram. ► (1) Carefully swing the lock on the flat ribbon cable conn…

6 Repairing the X Feeder modules
6.7 Operating Panel Assembly
76 Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017
► Insert the foil disposal drive, together with the foil
container, into the feeder module.
Run the cable as marked in the diagram:
► (1) Run the flat ribbon cable vertically downwards
and carefully fold it to the left.
► (2) Carefully fold the flat ribbon cable as marked
in the diagram.
Make sure that the blue surface at the end of the
cable is at the top.
► Thread the other cable under the flat ribbon
cable, to the second connection.
► (1) Insert the flat ribbon cable into the connection,
as far as the stop.
Make sure that the blue surface at the end of the
cable is at the top and that the flat ribbon cable
lies straight in the connection.
► Swing the lock on the connection down onto the
flat ribbon cable.
Make sure that the flat ribbon cable is fitted firmly
in the connection. Tug gently on the cable to
check.
► Check again whether the flat ribbon cable is fitted
straight in the connection.
If necessary, open the lock and correct the posi-
tion of the cable before closing the lock again.
► (2) Insert the connector carefully in the direction
of the arrow and as far as the stop, into the con-
nection shown.
Make sure that the smooth side of the connector
is at the top.
CAUTION!
Do not push the connector with force into the
connection, otherwise individual pins may
break off or be distorted.
.
► Fit the left side cover into place (see 6.3.2 "Fitting
the Left Side Cover" [}24]).
6.7.3 Removing the Operating Panel (12 mm)
► Carefully place the feeder module down on its left
side.
► Loosen the 2 screws marked in the diagram.
► Now carefully place the feeder module down on
its right-hand side.
► Remove the left side cover (see 6.3.1 "Removing
the Left Side Cover" [}23]).

6 Repairing the X Feeder modules
6.7 Operating Panel Assembly
Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017 77
► Loosen the 2 screws marked in the diagram.
► (1) Carefully swing the lock on the flat ribbon
cable connection up to the left and release the
flat ribbon cable.
Make sure that the lock is not pushed too far
back. The lock could break off if you do this.
► (2) Carefully pull the connector marked in the dia-
gram out of its connection in the direction of the
arrow. Pull on the connector and NOT on the
cable.
► Press the removal handle so that this springs out.
► Lever up the operating panel.
The operating field is caught slightly on the foil con-
tainer frame.
► Carefully spread the foil container frame apart.
► Carefully jog the operating panel to move it up
and out of the foil container frame.

6 Repairing the X Feeder modules
6.7 Operating Panel Assembly
78 Service Manual SIPLACE X-Feeder 4 - 88 mm 11/2017
► Pull both cables out of the foil container frame.
6.7.4 Fitting the Operating Panel (12 mm)
► Thread the cable into the foil container frame as
marked in the diagram.
The control panel gets caught slightly on the foil con-
tainer frame during insertion.
► Carefully spread the foil container frame apart.
► Carefully jog the control panel into the foil con-
tainer frame.