User Manual E-by-SIPLACE 用户手册.pdf - 第129页

User manual E by SIPLACE 3 Technical data and assemblies From software version SC 712.1 Edition 05/2019 3.5 Placement hea d 129 3.5.4 Vacuum pump Each Collect&Place head (SIPLACE CP14/12 /6) has its own vacuum genera…

100%1 / 324
3 Technical data and assemblies User manual E by SIPLACE
3.5 Placement head From software version SC 712.1 Edition 05/2019
128
3.5.3.4 Technical data
3
SIPLACE CP6
with component camera, type 30 GigE
Range of components
*a
*)a Please note that the component range that can be placed is also affected by the pad geometry, the cus-
tomer-specific standards and the packaging tolerances.
0201 to 27 x 27 mm²
Component specification
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
8.5 mm
*b
0.3 mm
0.15 mm
0.25 mm for components< 18 x 18 mm²
0.35 mm for components 18 x 18 mm²
0.14 mm for components < 18 x 18 mm²
0.2 mm for components 18 x 18 mm²
0.6 x 0.3 mm²
27 x 27 mm²
5 g
*)b 19 mm if one nozzle is removed, With PP head configuration only
Nozzle types 38xx, 39xx
X/Y accuracy
*c
*)c The accuracy value was measured using the vendor-neutral IPC standard
± 52.5 μm/3σ
Angular accuracy ± 0.225°/3σ
Illumination levels 5
Possible illumination level setting
256
5
User manual E by SIPLACE 3 Technical data and assemblies
From software version SC 712.1 Edition 05/2019 3.5 Placement head
129
3.5.4 Vacuum pump
Each Collect&Place head (SIPLACE CP14/12/6) has its own vacuum generator, which supplies
the holding and placement circuit with the required vacuum. The vacuum generator for the place-
ment heads functions according to the Venturi principle. When operated together with a vacuum
pump, the Collect&Place head (SIPLACE CP14/12/6) reduce the compressed air consumption
considerably. The running costs will fall according to the energy costs incurred.
3
3
Fig. 3.5 - 7 Location of the vacuum pump
(1) Location of the vacuum pump
PLEASE NOTE
The compressed air consumption values with the vacuum pump can be found in section
3.2.4
, page 105.
(1)
3 Technical data and assemblies User manual E by SIPLACE
3.5 Placement head From software version SC 712.1 Edition 05/2019
130
3.5.4.1 Safety instructions
3
3
WARNING
Please observe the warning label section 2.2.6, page 61.
WARNING
Please observe the safety instructions of the vacuum pump in the user manual sup-
plied.