User Manual E-by-SIPLACE 用户手册.pdf - 第235页
User manual E by SIPLACE 5 Working with the machine From software version SC 712.1 Edition 05/2019 5.11 Setting up t he feeder modules 235 5.11.3 Using the SI PLACE SmartFeeder E 5.11.3.1 Check the SIPLACE SmartFeeder E …
5 Working with the machine User manual E by SIPLACE
5.11 Setting up the feeder modules From software version SC 712.1 Edition 05/2019
234
On standby, the status display (item 2) lights up green if the feeder module is contained in the cur-
rent setup. If the feeder module is not contained in the current setup, the status display remains
off.
The SIPLACE SmartFeeder E is locked in position in the changeover table by a latch. The proce-
dure for removing feeder modules from the changeover table is as follows:
Pull the removal handle (item 1). The status display goes red and then the status display
goes out.
Use the removal handle to pull the feeder module out of the locking bar (item 3) and stop
bar (item 4).
Remove the feeder module. Pay attention to the centering bar (item 5).

User manual E by SIPLACE 5 Working with the machine
From software version SC 712.1 Edition 05/2019 5.11 Setting up the feeder modules
235
5.11.3 Using the SIPLACE SmartFeeder E
5.11.3.1 Check the SIPLACE SmartFeeder E before using it
5
Fig. 5.11 - 2 Check the SIPLACE SmartFeeder E before using it
(1) Cover foil rocker
(2) Pickup window
(3) Lever for raising and latching the pick-up window
Check the following points before you use a feeder module on the changeover table:
The feeder module must be in perfect condition.
Tap the cover foil rocker (item 1) lightly to make sure that it has not jammed.
Check that the area around the pickup window (item 2) is free from loose components.
Press the lever (item 3) forward slightly to open the pickup window (item 2). This will raise the
pick-up window slightly.
5
PLEASE NOTE
The tensioned cover foil continues to transport the tape when the tape has been inserted
and exposes the components.
Do not press the lever if a component tape is inserted.
(1)
(2)
(3)

5 Working with the machine User manual E by SIPLACE
5.11 Setting up the feeder modules From software version SC 712.1 Edition 05/2019
236
Close the pickup window (item 2), by returning the lever (item 3) to its original position.
Remove loose components from the changeover table with a brush or use a vacuum
cleaner with appropriate nozzle.
5
PLEASE NOTE
If the component tape is already inserted, cut it off flush with the front edge of the
feeder module.