User Manual E-by-SIPLACE 用户手册.pdf - 第259页
User manual E by SIPLACE 6 Station extensions From software version SC 712.1 Edition 05/2019 6.1 Nozzle change r 259 6.1.1.3 Position of nozzle changer for the SIPLACE CP14 6 Fig. 6.1 - 3 Position of nozzle changer for t…

6 Station extensions User manual E by SIPLACE
6.1 Nozzle changer From software version SC 712.1 Edition 05/2019
258
6.1.1.2 Technical data
6
Nozzle changer for the SIPLACE CP14
Number of nozzle holders 80
Number of nozzle magazines 4
Nozzle types 4xxx
Nozzle changeover time Approx. 2s per nozzle
Compressed air connection 0.45 MPa (4.5 bar)

User manual E by SIPLACE 6 Station extensions
From software version SC 712.1 Edition 05/2019 6.1 Nozzle changer
259
6.1.1.3 Position of nozzle changer for the SIPLACE CP14
6
Fig. 6.1 - 3 Position of nozzle changer for the SIPLACE CP14 - example
(1) Changeover table on location 1
(2) Changeover table on location 2
(NC) Nozzle changer
(RB) Reject bin
(PA) Placement area
(GA) Gantry
(2)
(1)

6 Station extensions User manual E by SIPLACE
6.1 Nozzle changer From software version SC 712.1 Edition 05/2019
260
6.1.1.4 Assembly
In E by SIPLACE machines, the nozzle changers are installed on the machine frame.
6
Fig. 6.1 - 4 Assembly position
(1) Sloping side points towards the changeover table COT insert
Align the nozzle changer so that the sloping side points towards the changeover table COT
insert.
6
WARNING
Risk of head crashes with mixed configurations!
There is a risk of head crashes with mixed configurations.
Only install the associated nozzle changer for each placement head, with the nozzle
magazines for the respective placement head.
(1)