User Manual E-by-SIPLACE 用户手册.pdf - 第79页
User manual E by SIPLACE 2 Operational safety From software version SC 712.1 Edition 05/2019 2.7 Safety featur es 79 2.7 Safety features 2.7.1 Protective covers The protective hoods and covers serve as protective devices…

2 Operational safety User manual E by SIPLACE
2.6 Additional safety instructions for the machines From software version SC 712.1 Edition 05/2019
78
2.6 Additional safety instructions for the machines
2.6.1 Safety instructions for docking the changeover table in or out
2
2
2
2
2.6.2 Safety instructions for emptying the waste tape container
The waste tape container must be pulled out of the changeover table for emptying. There is a risk
of catching your thumbs as you do so. To prevent this, observe the safety instructions in section
5.9.2
, page 228.
WARNING
Operation only with changeover table!
The placement machine may only be operated if there is a changeover table present and
docked at each location.
Fill any free locations with dummy feeder modules as described in section 2.7.5.1,
page 88.
WARNING
DANGER OF CRUSHING!
Risk of crushing limbs when docking and undocking the changeover table.
Always dock/undock the changeover table alone.
CAUTION
Risk of breaking handles!
Risk of breaking handles when transporting the changeover table.
When transporting the changeover table, do not lift it by its handles.
CAUTION
Risk of injuring limbs!
Risk of injuring limbs when docking and undocking.
When docking and undocking, make sure that there are no body limbs in the travel
area of the changeover table.

User manual E by SIPLACE 2 Operational safety
From software version SC 712.1 Edition 05/2019 2.7 Safety features
79
2.7 Safety features
2.7.1 Protective covers
The protective hoods and covers serve as protective devices which prevent unauthorized access
to the inside of the machine.
2
2
2
Fig. 2.7 - 1 Protective covers
(1) Protective cover location 1
(2) Protective cover location 2
The travel range of the gantry is protected with two covers which can be opened (items 1 and 2).
PLEASE NOTE
Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers
Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers on the Protective
Covers to be done every 12 months.
CAUTION
Risk of damage!
The protective covers and other covers could be damaged if too much force is exerted.
Do not stand on or climb up the protective covers and other covers.
(1)
(2)

2 Operational safety User manual E by SIPLACE
2.7 Safety features From software version SC 712.1 Edition 05/2019
80
Function 2
If the protective cover is swung upwards, the power supply to the gantry axes will be immediately
interrupted. The gantry axes stop moving. The message "Close cover" is displayed on the screen.
Close the protective covers and press the START button (item 2 in fig. 2.7 - 2), to continue
placement.
2
Fig. 2.7 - 2 Position of the start buttons (white) on the machine
(1) STOP button (black) on machine
(2) Start button (white) on the machine
(3) EMERGENCY STOP button
(2)