Printer 600 Machine Programming.pdf - 第116页
0$&+,1( 352*5$00 ,1* 0(183$5$ 0(7(56 1.116 User Manual Software Ve rsion 07SP04 Paste St art This parameter de termines the star t positi on of the p aste di spense measured from the centre line of the machi ne. Th…

0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 07SP04 User Manual 1.115
Tooling Deviation This parameter sets the extent of tooling deviation before a warning message
is posted.
Board Stop X This parameter determines the distance from the centre line of the machine to
the board stop position.
NOTE
Not used while the remote board stop is fitted.
Board Stop Y This parameter determines the distance from the fixed rail to the board stop
position.
NOTE
Not used while the remote board stop is fitted.
Right Feed Delay This parameter sets a time delay on the board stop to allow for irregular shaped
boards when fed from the right.
NOTE
Not used while remote board stop is fitted.
Board-At-Stop
Run-On
This parameter sets the period of time for which the belts continue to run after
the board has reached the board stop.
NOTE
Only used on printhead cover machines while high throughput conveyor ena-
bled.
Remote Board
Stop X
This parameter determines the displacement of the remote board stop from the
camera reference position.
NOTE
Only used while remote board stop is fitted.
Minimum Maximum Increment Default
0% 50% 0.25% 20%
Minimum Maximum Increment Default
0.0mm 255.0mm 0.1mm Half of the board length set in the board
file, (board located centrally)
Minimum Maximum Increment Default
20.0mm Board width - 15.0mm 0.1mm Two thirds of the board width
Minimum Maximum Increment
0 sec 3 secs 0.1 sec steps
Minimum Maximum Increment Default
0.0 Secs 1.0 Secs 0.1 Secs 0.3 Secs
Minimum Maximum Increment Default
Minimum board length ÷ 2 Board length 0.1mm Board length ÷ 2

0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.116 User Manual Software Version 07SP04
Paste Start This parameter determines the start position of the paste dispense measured
from the centre line of the machine. The limits depend on the type of stencil
fitted.
Paste Stop This parameter determines the stop position of the paste dispense measured
from the centre line of the machine. The maximum value depends on the type
of stencil fitted.
SPC Configuration This preference allows the user to set up the Machines SPC operation. On
selecting the SPC Configuration by pressing the Incr. or Decr. buttons, a window
opens and the menu bar changes.
NOTE
See the SPC Configuration section in this chapter for further details.
2Di Parameters For a list of all the 2Di parameters, refer to the 2D Inspection Chapter later in
this manual.
Minimum Maximum
Adapter Start Position Adapter Start Position
No Adapter -255.0mm No Adapter +255.0mm
255 -230.0mm 255 +230.0mm
Sanyo -210.0mm Sanyo +210.0mm
Heraeus -172.0mm Heraeus +172.0mm
249 -215.0mm 249 +215.0mm
Default - half the board length Default + half the board length
Minimum Maximum
Adapter Start Position Adapter Start Position
No Adapter -255.0mm No Adapter +255.0mm
255 -230.0mm 255 +230.0mm
Sanyo -210.0mm Sanyo +210.0mm
Heraeus -172.0mm Heraeus +172.0mm
249 -215.0mm 249 +215.0mm
Default - half the board length Default + half the board length

0$&+,1(352*5$00,1*
63&&21),*85$7,21
Software Version 07SP04 User Manual 1.117
SPC CONFIGURATION
When the cursor on the Edit Current Process Parameters page highlights the
SPC Configuration option and Incr. or Decr. are pressed an SPC Configuration
Window opens and two extra menu options become available:
Configuration
Window
The configuration window allows the user to setup the machines SPC operation.
Data Output Rate Two rates of data output are available as follows:
Every Cycle - Outputs SPC data every cycle except for the camera data, which
is output dependant upon the settings of the parameters start rate, sample rate
and start rate limit.
On Inspect - Outputs all SPC data at a rate dependant upon the settings of the
parameters start rate, sample rate and start rate limit.
Start Rate Limit Sets the amount of SPC output cycles at the start rate. When this limit is
reached the sample rate parameter becomes the active SPC output rate. The
range is 0-100, where 0 = continuous SPC output at the start rate.
NOTE
Setting both start rate limit and sample rate to zero causes continuous SPC
output at the start rate.
Start Rate Sets the initial SPC output rate, for setting up a line. If start rate is set to 10,
SPC data is output every 10 cycles until the start rate limit is reached, when the
rate becomes that set in the sample rate parameter. The range is 1-100.
Sample Rate Sets the rate of SPC output after the start rate limit has been reached. The
range is 0-100, where 0 = continuous SPC outputs at start rate. If sample rate
is set to 15, SPC data is output every 15 cycles after the start rate limit is
reached.
Edit
Outputs
Edit
Limits
Next Previous Incr. Decr. Exit
SPC Configuration Page
DATA OUTPUT RATE
START RATE
SAMPLE RATE
START RATE LIMIT
SPC DATA MODE
SPC FORMAT
UPDATE ON START-UP
ALIGN INSPECT MODE
EVERY CYCLE
1
10
10
NONE
WINDOWS
NO
PRE PRINT
cycles
cycles
cycles