Printer 600 Machine Programming.pdf - 第93页

0$&+,1 (352*5$0 0,1* 0(18 3$5 $0( 7(5 6 Software Version 07SP04 User Manual 1.93 Centre line of the image - centre justif ied image Image Y This p arameter defines the dimension in the Y axis f rom the fr ont inner…

100%1 / 128
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.92 User Manual Software Version 07SP04
and the stencil glue line at the front of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Mesh Rear This parameter sets the distance between the inner edge of the stencil frame
and the stencil glue line at the rear of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Mesh Left This parameter sets the distance between the inner edge of the stencil frame
and the stencil glue line at the left of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Mesh Right This parameter sets the distance between the inner edge of the stencil frame
and the stencil glue line at the right of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
X Justification This parameter defines the position of the image about the Image X parameter.
The image can be left, right or centre justified about Image X. Options are:
Y Justification This parameter defines the position of the image about the Image Y parameter.
The image can be front, rear or centre justified about Image Y. Options are:
Image X This parameter defines the dimension in the X axis from the right inner edge of
the stencil frame to either:
Right hand edge of the image - right justified image
Left hand edge of the image - left justified image
Minimum Maximum Increment Default
0.0mm Stencil Length - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Stencil Length - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Stencil Width - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Stencil Width - 250.0mm 0.1mm 38.0mm
Option Default
Left Centre
Right
Centre
Option Default
Front Centre
Rear
Centre
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 07SP04 User Manual 1.93
Centre line of the image - centre justified image
Image Y This parameter defines the dimension in the Y axis from the front inner edge of
the stencil frame to either:
Front edge of the image - front justified image
Rear edge of the image - rear justified image
Centre line of the image - centre justified image
Barcode Y This parameter defines the dimension between the centre of the barcode to the
outer rear edge of the stencil frame or adaptor.
Screen Adapter The type of screen adapter needed, if any, for the stencil to be used for this
product.
NOTE
This parameter is not displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Screen Image The position of the image in the stencil frame. Options are:
NOTE
This parameter is not displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Custom Screen This option allows user definable stencil image positions. Selection of this
parameter activates the Print Area Length, Print Area Width and Distance To
Image. Options are:
Minimum Maximum Increment Default
60.0mm Stencil Length - 100.0mm 0.1mm 330.4mm
Minimum Maximum Increment Default
60.0mm Stencil Width - 100.0mm 0.1mm 330.4mm
Minimum Maximum Increment Default
10.0mm Stencil Length - 10.0mm 0.1mm 97.0mm
Options Available
None
255
Sanyo
Heraeus
20 X 20
12 X 12
Options Available Notes
Edge Justified Permitted for Sanyo and Fuji frames only
Centre Justified -
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.94 User Manual Software Version 07SP04
NOTE
This parameter is not displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Print Area Length This is the maximum printable distance in the Y direction, ie the maximum
distance the squeegee can travel, front to back.
NOTE
This parameter field only appears if Custom Screen has been selected.
Print Area Width This is the maximum length of squeegee that could be fitted to the printer, taking
into account stencil frame and the amount of mesh surrounding the mask. This
is also the maximum length of paste that can be dispensed.
NOTE
This parameter field only appears if Custom Screen has been selected.
Distance to Image The meaning of this parameter varies, depending on whether an image is centre
or edge justified. For centre justified images, the dimension is the distance from
the outside rear of the stencil frame to the centre of the image plus half the board
width. For edge justified images, the dimension is the distance from the outside
rear of the stencil frame to the front edge of the board.
NOTE
This parameter field only appears if Custom Screen has been selected.
Board Width This parameter sets the rail width for this particular product. It is also used to
set a default value for the print stroke, the clean screen, the board stop position
in the Y direction and the AutoFlex rows. The maximum value depends on the
Options Available
Enabled
Disabled
Minimum Maximum Increment
100.0mm 508.5mm 0.1mm
Minimum Maximum Increment
100.0mm 510.0mm 0.1mm
Minimum Maximum Increment
306.0mm 645.0mm 0.1mm