B01 Shape Data (B01_13)
0107-001 2-80 Tg0502-PM-CL
(B01_13) Electrical Group Data
Set the electrode group on a component.
Applicable Components: BGA/CSP
(1) Electrical Group Type No.
Set the No. for the electrode type data included in this group.
Unit: type
Data Input Range: 1 to 3
Fig.B172
Type No.
1
Grp
No.
1
(2) Electrical Group Grp Posn X [mm], Y [mm]
Set the center position of a ball group (based on the center of the
mold) in the data box.
Unit: mm
Data Input Range:
X: 99.999 to +99.999
Y: 99.999 to +99.999
As the center of a ball group is located at the center of the mold in normal
cases, the coordinates X and Y become "0" (zero). (X, Y = 0, 0)
Fig.B173
Grp Posn
X [mm]
99.999
Grp
No.
1
Grp Posn
Y [mm]
99.999
Fig. B171 Edit Window (Example) for BGA/CSP Components
Fig. B174
B01 Shape Data (B01_13)
0107-001 2-81 Tg0502-PM-CL
Fig.B175
# of Rows
[pcs.]
99.999
Grp
No.
1
# of Cols
[pcs.]
99.999
(3) Electrical Group # of Rows [pcs.], # of Cols [pcs.]
Set the number of rows and columns in which balls are arrayed.
Unit: pieces
Data Input Range: 1 to 255
Fig.B177
Row Pitch
[mm]
00.000
Grp
No.
1
Col Pitch
[mm]
00.000
(4) Electrical Group Row Pitch [mm], Col Pitch [mm]
Set the pitches at which balls are arrayed in each row and column.
Unit: mm
Data Input Range: 0 to 99.999
Fig. B176
Fig. B178
B01 Shape Data (B01_13)
0111-002 2-82 Tg0502-PM-CL
(5) Electrical Group Missing Elctd Set
Select the missing pattern of the electrical contacts from the fol-
lowing options.
No Missing Cmpnt Normal Vertical Symmetry
Bilateral Symmetry Radial Symmetry
Setting this data, the instruction for the missing electrode block
can be simplified
Fig.B179
Missing
Elctd Set
No Missing Cmpnt
Grp
No.
1
Converted in the
internal recognition
Fig. B180