OM-1076-001.pdf - 第37页
(13) Nozzle Change Select one of the following options to designate the rate of the nozzle change speed reduction when a component is picked up. Full Speed 10% Decr 20% Decr 30% Decr 40% Decr 50% Decr 60% Decr 70% Decr 8…

(10) Pl Descent Dclr 2 Stroke [mm]
Set a parameter to designate the stroke in the data box so that the X/
Y beam descends along with the stoke and at a very slow speed (speed
reduction specified in the "Pl descent dclr 2").
Unit: mm
Data Input Range: 1.00 to 5.00
A02 Control Data (A02_01)
0206-002 2-18 Tg0502-PM-CL
Fig.B22
Pl descent dclr 2 stroke [mm]
1.00
Use this function when a press-fit or insertion component must be placed.
(11) Pl Ascent
Select one of the following options to designate the rate of the head
ascending speed reduction after the component placement.
Full Speed 10% Decr 20% Decr 30% Decr 40% Decr
50% Decr 60% Decr 70% Decr 80% Decr 90% Decr
(12) Nozzle Rotation
Select one of the following options to designate the rate of nozzle
rotation speed reduction when a component is picked up.
Full Speed 10% Decr 20% Decr 30% Decr 40% Decr
50% Decr 60% Decr 70% Decr 80% Decr 90% Decr
Fig.B25
Nozzle rotation Full Speed
Fig.B24
Pl ascent Full Speed
Nozzle
Component
Reflection of "Pl Descent Dclr 1"
Reflection of "Pl Descent Dclr 2"
"Pl Descent Dclr 2 Stroke"
Pass Line
(Lower or Upper Pass Line)
Side View
Fig. B23

(13) Nozzle Change
Select one of the following options to designate the rate of the nozzle
change speed reduction when a component is picked up.
Full Speed 10% Decr 20% Decr 30% Decr 40% Decr
50% Decr 60% Decr 70% Decr 80% Decr 90% Decr
(14) Recognition Time [sec] (Disable)
Set the approximate time required for component recognition process-
ing in the data box.
Unit: second
Data Input Range: 0.00 to 9.99
This set parameter is used to process the optimization.
(15) Pu Retention Time [sec]
Set the retention time for the nozzle at the lower limit when a compo-
nent is picked up.
Unit: second
Data Input Range: 0.00 to 1.99
This function can be used when the pick-up is not stable due to the influ-
ence of the component pick-up surface or some incompatibility with the
nozzle.
(16) Pl Retention Time [sec]
Set the retention time for the nozzle at the lower limit when a compo-
nent is placed.
Unit: second
Data Input Range: 0.00 to 1.99
A02 Control Data (A02_01)
0111-002 2-19 Tg0502-PM-CL
Fig.B26
Nozzle change
Full Speed
Fig.B27
Recognition time [sec]
0.00
Fig.B28
Pu retention time [sec]
0.00
Fig.B29
Pl retention time [sec]
0.00

(17) Cmpnt Detection (Sensor)
Set whether to judge the pick-up quality with the vacuum sensor.
"DISABLE" or "ENABLE" can be selected.
When the nozzle selected in "Selected NOZZLE" meets one of the re-
quirements described in the table below, "DISABLE" is selected auto-
matically.
Table B11
(18) Air blow
From the following items, select whether or not to air blow when the
component is placed.
Enable Disable
(19) Air blow off timing [mm]
Set the position at which the air blow is turned off.
This function is used when the nozzle error occurs where component
is brought back.
Unit: mm
Data Input Range: 0.0 to 9.9
A02 Control Data (A02_01)
0206-003 2-20 Tg0502-PM-CL
Fig.B30
Cmpnt detection (Sensor)
Disable
Fig.B30-1
Air blow
Enable
Fig.B30-2
Air blow off timing [mm]
0.0
Fig. B30-3
Item Condition Remarks
Nozzle ID EC** Mechanical Chuck Nozzle
EE** Mechanical Chuck Nozzle
Area of Pick-Up Hole Less then 0.7854mm
2
Total Area of Pick-Up Hole