OM-1076-001.pdf - 第73页

(B01_06) Edge Data Set edge shapes at each detectable position in the "Shape", "Detec- tion Posn X", and "Detection Posn Y" for Edges "1", "2", "3", and "4…

100%1 / 237
(a) Set parameters only when "Manual" is selected in the "Corner data
des" text box for cylindrical or square components.
(b) Set parameters only when "Normal (Rectangle)" is selected in the
"Component Type" text box for deform (simple) components.
(c) It is not required to set any parameters when "No Chamfer" is se-
lected in the "Shape" text box.
(d) Set parameters for "Dim X" and "Dim Y" even when "No Det" is set for
"Shape" of a corner indicated below as A. In this case, the dimen-
sions of a similar corner are regarded as Dimensions X and Y.
Top View of Component
(e) Set "No Det (Defective)" when a component mold has two similar
corners shown below as A and B. In this case, set the size of C in
"Dim X" and set the size of D in "Dim Y".
Top View of Component
B01 Shape Data (B01_05)
0107-001 2-48 Tg0502-PM-CL
Fig. B99
Fig. B100
(B01_06) Edge Data
Set edge shapes at each detectable position in the "Shape", "Detec-
tion Posn X", and "Detection Posn Y" for Edges "1", "2", "3", and "4".
Be sure to select two or more edges and set parameters for them as
edge data.
Edges 1, 2, 3, and 4
The following shows the positional relation of a component based
on the packaged posture.
Top View of Component
Applicable Components: Deform (Simple)
Set parameters only when "Normal (Rectangle)" is selected in the "Cmpnt
Type" text box.
B01 Shape Data (B01_06)
0107-001 2-49 Tg0502-PM-CL
Fig. B101 Edit Window (Example) for Deform (Simple) Components
Fig. B102
(1) Shape
Select the following parameters (edge shapes at each detectable po-
sition).
Table B13
Straight
Convexoconcave
No Detection Select this when the component mold has
slanted edges (not straight) and the edge
detection positions described in "(2) Detec-
tion Posn X and Y" cannot be specified. In
this case, the component center is calcu-
lated based on the result of the opposite
edge detection and according to the com-
ponent size.
Components without any straight edge cannot be recognized by the edge
detection function.
(2) Detection Posn X [mm] and Y [mm]
Set edge detectable positions X and Y originating from the center of
the mold.
When the center of the mold is assumed as an origin, the sign "+" or "-
" must be affixed to the coordinates of the edge detectable position as
shown below.
Top View
B01 Shape Data (B01_06)
0107-001 2-50 Tg0502-PM-CL
Fig. B103
Shape
Straight
Straight
Convexoconcave
Convexoconcave
No.
1
2
3
4
Fig. B104
Detection Posn
X [mm]
+00.000
+00.000
-01.400
+02.300
Detection Posn
Y [mm]
+00.000
+00.000
-01.200
+01.000
No.
1
2
3
4
Fig. B105