00196962-04-BA-SX12-V2-EN.pdf - 第232页

5 Working with the machine User manual SIPLACE SX1/SX2 5.3 Switching on the SIPLACE line From software version SC 706.1 SP1 Version 10/2014 232 5 Fig. 5.3 - 1 "Production" view after loading the station sof twa…

100%1 / 370
User manual SIPLACE SX1/SX2 5 Working with the machine
From software version SC 706.1 SP1 Version 10/2014 5.3 Switching on the SIPLACE line
231
5.3.3 User classification
Certain functions or menus may only be executed or can only accessed by specially trained per-
sonnel. A differentiation is made between the following operator levels:
Production
Advanced production
Service (customer)
Service (SIPLACE)
The operator levels "Advanced production" and "Service (customer)" can be password protected.
The operator level "Service (SIPLACE)" is already password protected.
For a detailed description of the user classification, refer to section 5.1
, page 223.
5.3.4 Switching on the station and starting the station software user interface
5
Switch the station on at the main power switch.
After switching on, check whether the manometers show the required operating pressure.
The station computer software is loaded and the "Production" view of the station software is
shown for the "Production" operator level (see following diagram).
CAUTION
Communication problems when switching on the station!
Early switching on of station can lead to communication problems.
Only switch the station on if the monitor of the SIPLACE Pro computer shows the
"Desktop",
5 Working with the machine User manual SIPLACE SX1/SX2
5.3 Switching on the SIPLACE line From software version SC 706.1 SP1 Version 10/2014
232
5
Fig. 5.3 - 1 "Production" view after loading the station software (example of SIPLACE X4i shown)
The status field (see section 5.5.1, page 237) shows the current status of the station and the action
to be performed.
Press the start button when you see the request "Press Start button".
Start buttons can be found on the input side, output side and on the operating panels to the
left and right of the station.
A reference run will be performed. After completion of this reference run, the station is ready
for operation.
The icon will be shown in the working area of the user interface (enabled).
User manual SIPLACE SX1/SX2 5 Working with the machine
From software version SC 706.1 SP1 Version 10/2014 5.3 Switching on the SIPLACE line
233
5.3.5 Action by Machine Start Button
The action performed by the start button can be set.
Open the "Check sensors and functions" view (see section 5.5.3, page 238).
The following settings are possible:
Start production automatically 5
Standard setting.
Pressing the start button automatically begins the production process.
Do not change production status 5
This is used, for example, to calibrate and test the machine
Pressing the start button simply closes the electricity circuit; production is not started immediately.
5
5.3.6 "Switching on the SIPLACE line" flow chart
The following flow diagram shows the actions performed after the SIPLACE line has been
switched on.
CAUTION
Machine functions can be directly started via the GUI, irrespective of the start button set-
ting. If the electrical circuit has already been closed, you do not need to confirm with the
start button again.