6 Station extensions User ma nual SIPLACE SX1/SX2 6.19 Capacity on Demand From software version SC 706.1 SP1 Version 10/2014 354 6.19.4 Head configurations 6 SIPLACE SX + Gantry Heads 1 C&P20 A CPP (Low) CPP (High) *…

User manual SIPLACE SX1/SX2 6 Station extensions
From software version SC 706.1 SP1 Version 10/2014 6.19 Capacity on Demand
353
6.19.2 SIPLACE Capacity On Demand business models
The Peak-Demand models addresses the need to cover short-term fluctuations with existing SI-
PLACE SX lines. The other model, Floating-Demand, provides customers with an alternative to
the standard package, thereby improving their financial flexibility, increasing asset productivity and
allowing full exploitation of the benefits offered with a SIPLACE SX solution.
6.19.3 Overview of SIPLACE SX machines
The SIPLACE SX must be prepared for a gantry upgrade. The SIPLACE SX machines are avail-
able in different variants.
6
The head configurations available may be limited, according to the design concerned.
Machine type Gantries Description
SIPLACE SX +
Without gan-
try
The machine is prepared for a gantry upgrade (SX1), i.e.
a trailing cable and two Gantry Control Units (GCU) are
preinstalled for one gantry.
SIPLACE SX +
Prepared
Without gan-
try
The machine is prepared for a gantry upgrade (SX1/2),
i.e. two trailing cables and three Gantry Control Units
(GCU) are preinstalled for two gantries.
SIPLACE SX1
unprepared
One gantry The machine is not prepared for a gantry upgrade (SX1),
i.e. the trailing cable and two Gantry Control Units (GCU)
are preinstalled for one gantry. An upgrade to SIPLACE
SX2 needs to be performed by the SIPLACE Service
team.
SIPLACE SX1
prepared
One gantry The machine is prepared for a gantry upgrade (SX2), i.e.
two trailing cables and three Gantry Control Units (GCU)
are preinstalled for two gantries.
SIPLACE SX2
Two gantries The machine can be torn down to give a SIPLACE SX1
Prepared. The machine is then prepared for a gantry
upgrade to SX2, i.e. two trailing cables and three Gantry
Control Units (GCU) are available.

6 Station extensions User manual SIPLACE SX1/SX2
6.19 Capacity on Demand From software version SC 706.1 SP1 Version 10/2014
354
6.19.4 Head configurations
6
SIPLACE SX +
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
*a
Without stationary camera
TH
*b
SIPLACE SX + Prepared
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
SIPLACE SX1
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
with upgrade kit from SIPLACE Service
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
SIPLACE SX1 prepared
Gantry
Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
SIPLACE SX 2
Gantry Heads
1
C&P20 A
CPP
(Low)
CPP (High)
a
With stationary camera
CPP (High)
a
Without stationary camera
TH
b
TH
b
2
C&P20 A
CPP
(Low)
CPP (High)
a
Without stationary camera
TH
b
CPP
(High)
TH
b
*)a CPP (high), TH and stationary camera require outer table position
*)b CPP with stationary camera requires CPP (high) and outer table position

User manual SIPLACE SX1/SX2 Index
Version 10/2014
355
Index
Symbols
"Head crash" label
. . . . . . . . . . . . . . . . . . . . . . .52
"Switching on the SIPLACE line" flow chart
. . .233
Numerics
12 segment Collect&Place head
Angular accuracy
. . . . . . . . . . . . . . . . . . . .340
Blast air valve
. . . . . . . . . . . . . . . . . . . . . . .338
C&P component camera, type 28 (18 x 18) dig-
ital or type 30 (27 x 27) digital, high-resolution
.
339
Component camera type
. . . . . . . . . . . . . .340
Component range
. . . . . . . . . . . . . . . . . . . .340
Component specification
. . . . . . . . . . . . . .340
Illumination level
. . . . . . . . . . . . . . . . . . . . .340
Intermediate distributor board
. . . . . . . . . .339
Nozzle types
. . . . . . . . . . . . . . . . . . . . . . . .340
Possible illumination level settings
. . . . . . .340
Programmed set-down force
. . . . . . . . . . .340
Silencer
. . . . . . . . . . . . . . . . . . . . . . . . . . .338
Star drive - DR motor
. . . . . . . . . . . . . . . . .339
Star with 12 sleeves, star axis
. . . . . . . . . .338
Turning station, DP axis
. . . . . . . . . . . . . . .338
Vacuum generator
. . . . . . . . . . . . . . . . . . .338
Valve adjustment drive
. . . . . . . . . . . . . . . .339
X/Y accuracy
. . . . . . . . . . . . . . . . . . . . . . .340
Z axis motor
. . . . . . . . . . . . . . . . . . . . . . . .339
24 mm X tape feeder module . . . . . . . . . . . . . .154
2x8 mm X tape feeder module
. . . . . . . . . . . . .150
32 mm X tape feeder module
. . . . . . . . . . . . . .155
44 mm X tape feeder module
. . . . . . . . . . . . . .156
56 mm X tape feeder module
. . . . . . . . . . . . . .157
72 mm X tape feeder module
. . . . . . . . . . . . . .158
8 mm X tape feeder module
. . . . . . . . . . 149, 151
88 mm X tape feeder module
. . . . . . . . . . . . . .159
A
Abbreviations
. . . . . . . . . . . . . . . . . . . . . . . . . . 31
Action by start button
. . . . . . . . . . . . . . . . . . . 233
Adapter for the X-Series feeder modules
166, 167,
168
adapter plate for label presenter
. . . . . . . . . . . 166
adapter plate for reject conveyor
. . . . . . . . . . . 168
adapter plate, 16.5 mm
. . . . . . . . . . . . . . . . . . 167
adapting the component trolley to the PCB conveyor
height
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Adjusting the empty tape duct to the component
height
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
Advanced production
. . . . . . . . . . . . . . . . . . . 231
air cushion transport system
. . . . . . . . . . 204, 216
Alert
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
alert information, colors
. . . . . . . . . . . . . . . . . . 245
ambient conditions
Ambient pressure
. . . . . . . . . . . . . . . . . . . . 97
Ambient conditions for machine operation
. . . . 99
Ambient conditions for packaging, transportation
and storage
. . . . . . . . . . . . . . . . . . . . . . . . . 99
Ambient pressure
. . . . . . . . . . . . . . . . . . . . . . . 97
Angular accuracy
. . . . . . . . . . . . . . . . . . . . . . . 94
A-Placement
. . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Assembly position for the stationary cameras
IC and FC camera
. . . . . . . . . . . . . . . . . . 139
Assembly positions of MultiStar in the machine
116
assembly positions of SIPLACE MultiStar
. . . 114
Atmospheric humidity
. . . . . . . . . . . . . . . . . . . . 97
authorized employees.
. . . . . . . . . . . . . . . . . . . 90
Automatic circuit breaker F1
. . . . . . . . . . . . . . . 86
Automatic width adjustment
. . . . . . . . . . . . . . 134
Avoiding track errors
. . . . . . . . . . . . . . . . . . . . 276
B
basic view
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Boards being processed
. . . . . . . . . . . . . . . . . 237
bumper detection
. . . . . . . . . . . . . . . . . . . . . . . 69
buttons
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67