2 Operational safety User manual SIPLACE SX1/SX2 2.10 Energy state of the machine after switching off at the main power switch From software version SC 706.1 SP1 Version 10/2014 84 2.10.1 Machine switched off at the main…

User manual SIPLACE SX1/SX2 2 Operational safety
From software version SC 706.1 SP1 Version 10/2014 2.10 Energy state of the machine after switching off at the main power switch
83
2.10 Energy state of the machine after switching off at the
main power switch
2
Fig. 2.10 - 1 Position of the power supply on the machine
2
2
(1) Main switch
DANGER
Dangerous voltage levels!
The machine is supplied with 3 x 200 V~, 3 x 208 V~, 3 x 220 V~, 3 x 230 V~, 3 x 380 V~,
3 x 400 V~ or 3 x 415 V~ ± 5 %, 50/60 Hz mains voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power
switch.
Incorrect handling of this machine can therefore result in death or severe injury or consid-
erable damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly EN
60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own coun-
try.
The covers over the power supply unit may ONLY be opened by appropriately quali-
fied and trained personnel.
(1)

2 Operational safety User manual SIPLACE SX1/SX2
2.10 Energy state of the machine after switching off at the main power switch From software version SC 706.1 SP1 Version 10/2014
84
2.10.1 Machine switched off at the main switch, but still connected
2
2
Fig. 2.10 - 2 Power supply unit, front view
(1) Service socket (X98)
(2) Fuse for service socket (F1)
(3) Main switch (Q1)
DANGER
Lethal voltages!
Incorrect handling of the machine can therefore result in death or severe injury or consid-
erable damage to equipment.
The following components still carry potentially lethal voltages even if the main power
switch is switched off:
– Mains connection terminals in the transformer unit L1, L2 and L3 of main switch Q1
– Service socket X98
– F1 automatic circuit breaker for the service socket
– The color of all individual wires, which still carry potentially lethal voltages even if the
main power switch is switched off, is brown.
(3)
(1)
(2)

User manual SIPLACE SX1/SX2 2 Operational safety
From software version SC 706.1 SP1 Version 10/2014 2.10 Energy state of the machine after switching off at the main power switch
85
2
Fig. 2.10 - 3 Power supply unit, side view
(1) Terminals (X99) for the power supply cable
(1)