3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Ambient conditions for machine operation
3
3.2.3 Electrical ratings
3
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75 % (no higher than 45% on average to prevent any
possibility of condensation on the machine)
Ambient pressure > 750 mbar (corresponds to 2500 m above mean sea level)
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 200 V~ ± 10 %; 50 Hz (North
Japan)
*a
3 x 220 V~ ± 10 %; 60 Hz (South Japan)
3 x 208 V~ ± 10 %; 50/60 Hz (U.S.A)
a
3 x 230 V~ ± 10 %; 50/60 Hz
3 x 380 V~ ± 10 %; 50/60 Hz
3 x 400 V~ ± 10 %; 50/60 Hz (Europe)
3 x 415 V~ ± 10 %; 50/60 Hz
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
Mains power connection Cable 5 x 4 mm² with CEKON connector 5 x 32 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3 x 380 V~ / 400 V~ / 415 V~)
Energy consumption
Energy consumption
without vacuum pump
Energy consumption
with vacuum pump
*b
Nominal apparent
power
SIPLACE SX1
SIPLACE SX2
1.8 kVA
2.4 kVA
3.0 kVA
3.6 kVA
Nominal active power
SIPLACE SX1
SIPLACE SX2
1.2 kW
1.6 kW
2.0 kW
2.4 kW
*)a Connection at terminals 3 x 204 VAC on transformer T1
*)b Vacuum pump for C&P20 head only.
3 Technical data and assemblies User manual SIPLACE SX1/SX2
3.2 Ambient conditions and connection values From software version SC 706.1 SP1 Version 10/2014
98
3.2.4 Compressed air supply and compressed air specification
3
Compressed air supply
Compressed air pressure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" inner thread (pipe thread) with 1/2" hose connection
Compressed air consumption
*a
Placement head configura-
tion
Compressed air
consumption
*b
without vacuum pump
Compressed air
consumption
b
with vacuum pump
*c
SIPLACE SX2
SIPLACE SX1
C&P20 / C&P20
CPP / CPP
CPP / TH
TH / TH
C&P20
CPP
TH
490 Nl/min
240 Nl/min
240 Nl/min
200 Nl/min
280 Nl/min
140 Nl/min
100 Nl/min
200 Nl/min
100 Nl/min
Compressed air specification according to ISO 8573
Particle size
(ISO Class 3)
5 µm
Particle density
(ISO Class 3)
5 mg/m³
Maximum oil content
(ISO class 1)
Particle density 0.01 mg/
Pressure dewpoint (ISO class 4) Dewpoint + 3°
*)a Average consumption values
*)b Under normal atmospheric conditions at 20°C and 1013 hPa.
*)c Vacuum pump for C&P20 head only.
User manual SIPLACE SX1/SX2 3 Technical data and assemblies
From software version SC 706.1 SP1 Version 10/2014 3.3 Dimensions and weight
99
3.3 Dimensions and weight
3.3.1 Technical data - dimensions and weight
3
Length of the machine
SX1/SX2 1500 mm
Width of the machine
SX1/SX2
*a
2475 mm
Height of the machine
with indicator lamp
With folded-up protective covers
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
max. 1765 mm
1980 mm
2010 mm
2030 mm
Machine ground clearance
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
120 mm ± 15 mm
150 mm ± 15 mm
170 mm ± 15 mm
Weight of SX
*b
SX1 with 2x component trolley 60
SX1 with 2x component trolley 60 (fully configured)
SX2 with 2x component trolley 60
SX2 with 2x component trolley 60 (fully configured)
2482 kg
2806 kg
2532 kg
2856 kg
Floor space for SX
a
SX1/SX2 with 2x component trolley 60 3.71 m²
The load per unit area calculation included an additional working space
of 0.5 m on each side of the machine.
Load per unit area for SX
c
SX1
SX2
6.1 kN/m²
6.2 kN/m²
The load per unit area calculation includes an additional working space
of 1.0 m on each side of the machine.
Load per unit area for SX
c
SX1
SX2
4.7 kN/m²
4.8 kN/m²
Number of machine feet 4
*)a Standard configuration: 1 component trolley inside and 1 component trolley outside with handles folded down.
*)b Standard configuration: 1 component trolley inside, 1 component trolley outside and single conveyor.