00196962-04-BA-SX12-V2-EN.pdf - 第97页

User manual SIPLACE SX1/SX2 3 Technical data and assemblies From software version SC 706.1 SP1 Version 10/ 2014 3.2 Ambient conditions and connection values 97 3.2 Ambient conditions and connection values 3.2.1 Ambient c…

100%1 / 370
3 Technical data and assemblies User manual SIPLACE SX1/SX2
3.1 Performance data for SIPLACE SX1/SX2 From software version SC 706.1 SP1 Version 10/2014
96
3.1.4 Component feeding
3
3
Feeder locations
Component trolley with 60 tracks
Component trolley with 30 tracks
60 feeders with 8 mm
30 feeders with 8 mm
Component trolley changeover time < 1 minute
Max. component feeding
(2 component trolleys on the SIPLACE SX)
2 component trolleys with tape reel holder and
integral waste tape bins:
When using a waffle pack changer:
120 locations for feeders with 8 mm.
90 locations for feeders with 8 mm.
Feeder module types (SIPLACE X) Tape feeder modules, tray feeders (with X reject - conveyor
adapter),
linear vibratory feeders and label feeders.
feeding capacity
(2 component trolleys on the SIPLACE SX)
120 tape feeder modules 4 mm X
120 tape feeder modules 8 mm X
60 tape feeder modules Smart Feeder 2x8 mm X
60 tape feeder modules, Smart Feeder 12 mm X
60 tape feeder modules, Smart Feeder 16 mm X
40 tape feeder modules 24 mm X
30 tape feeder modules 32 mm X
24 tape feeder modules 44 mm X
20 tape feeder modules 56 mm X
16 tape feeder modules 72 mm X
12 tape feeder modules 88 mm X
User manual SIPLACE SX1/SX2 3 Technical data and assemblies
From software version SC 706.1 SP1 Version 10/2014 3.2 Ambient conditions and connection values
97
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Ambient conditions for machine operation
3
3.2.3 Electrical ratings
3
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75 % (no higher than 45% on average to prevent any
possibility of condensation on the machine)
Ambient pressure > 750 mbar (corresponds to 2500 m above mean sea level)
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 200 V~ ± 10 %; 50 Hz (North
Japan)
*a
3 x 220 V~ ± 10 %; 60 Hz (South Japan)
3 x 208 V~ ± 10 %; 50/60 Hz (U.S.A)
a
3 x 230 V~ ± 10 %; 50/60 Hz
3 x 380 V~ ± 10 %; 50/60 Hz
3 x 400 V~ ± 10 %; 50/60 Hz (Europe)
3 x 415 V~ ± 10 %; 50/60 Hz
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 25 A to max. 3 x 32 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
3 x 16 A characteristic C
Mains power connection Cable 5 x 4 mm² with CEKON connector 5 x 32 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 5 x 16 A (3 x 380 V~ / 400 V~ / 415 V~)
Energy consumption
Energy consumption
without vacuum pump
Energy consumption
with vacuum pump
*b
Nominal apparent
power
SIPLACE SX1
SIPLACE SX2
1.8 kVA
2.4 kVA
3.0 kVA
3.6 kVA
Nominal active power
SIPLACE SX1
SIPLACE SX2
1.2 kW
1.6 kW
2.0 kW
2.4 kW
*)a Connection at terminals 3 x 204 VAC on transformer T1
*)b Vacuum pump for C&P20 head only.
3 Technical data and assemblies User manual SIPLACE SX1/SX2
3.2 Ambient conditions and connection values From software version SC 706.1 SP1 Version 10/2014
98
3.2.4 Compressed air supply and compressed air specification
3
Compressed air supply
Compressed air pressure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" inner thread (pipe thread) with 1/2" hose connection
Compressed air consumption
*a
Placement head configura-
tion
Compressed air
consumption
*b
without vacuum pump
Compressed air
consumption
b
with vacuum pump
*c
SIPLACE SX2
SIPLACE SX1
C&P20 / C&P20
CPP / CPP
CPP / TH
TH / TH
C&P20
CPP
TH
490 Nl/min
240 Nl/min
240 Nl/min
200 Nl/min
280 Nl/min
140 Nl/min
100 Nl/min
200 Nl/min
100 Nl/min
Compressed air specification according to ISO 8573
Particle size
(ISO Class 3)
5 µm
Particle density
(ISO Class 3)
5 mg/m³
Maximum oil content
(ISO class 1)
Particle density 0.01 mg/
Pressure dewpoint (ISO class 4) Dewpoint + 3°
*)a Average consumption values
*)b Under normal atmospheric conditions at 20°C and 1013 hPa.
*)c Vacuum pump for C&P20 head only.