00196962-04-BA-SX12-V2-EN.pdf - 第250页

5 Working with the machine User manual SIPLACE SX1/SX2 5.7 Indicator lamps with horn From software version SC 706.1 SP1 Version 10/2014 250 The nozzle setup is not com- plete. Respective side White: 500 -500 Green: -- Re…

100%1 / 370
User manual SIPLACE SX1/SX2 5 Working with the machine
From software version SC 706.1 SP1 Version 10/2014 5.7 Indicator lamps with horn
249
5.7.2 Status displays and their meanings
5
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
The machine is producing Both sides White: --
Green: On
Red: Off
Yellow: Off
Green: On
The machine is waiting for a
board at input.
Both sides White: --
Green: 700 - 700
Red: Off
Yellow: Off
Green: 500 - 500
The machine has been stopped
with the stop button; The start
button must be pressed to con-
tinue production.
Both sides Not configured Red: Off
Yellow: Off
Green: 500 - 500
Fiducial manipulation by the
operator required.
Both sides White: --
Green: 100 - 100
Red: Off
Yellow: 500-500
Green: Off
The machine is waiting for a
recipe or is waiting for machine
preparation after receiving a
recipe.
Both sides White: --
Green: 100 - 100
Red: Off
Yellow: Off
Green: 500 - 500
The machine is preparing pro-
duction (check nozzle status,
feeder modulerecognition).
Both sides White: --
Green: 100 - 100
Red: Off
Yellow: Off
Green: 500 - 500
An alternative pickup position
will be used.
Respective side White: 100 -100
Green: --
Red: Off
Yellow: On
Green: On
A board needs to be taken out
of the output conveyor (e.g. for
inspection).
Respective side White: 500 -500
Green: 700 -700
Red: Off
Yellow: Off
Green: 500 - 500
The PCB conveyor is jammed
(successor machine is waiting
for boards).
Respective side White: --
Green: 700 -700
Red: Off
Yellow: Off
Green: 500 - 500
More than one pickup position
with the same components is
disabled but there is more than
one pickup position available
for use.
Respective side White: 500 -500
Green: --
Red: Off
Yellow: On
Green: On
Setup verification is required
for at least one pickup position.
Respective side White: 500 -500
Green: --
Red: Off
Yellow: 500 - 500
Green: Off
5 Working with the machine User manual SIPLACE SX1/SX2
5.7 Indicator lamps with horn From software version SC 706.1 SP1 Version 10/2014
250
The nozzle setup is not com-
plete.
Respective side White: 500 -500
Green: --
Red: Off
Yellow: On
Green: On
The last available pickup posi-
tion is being used or there is no
pickup position left for this com-
ponent. The machine will con-
tinue to produce while there are
still other components which
can be placed.
Respective side White: 100 -200
Green: --
Red: Off
Yellow: On
Green: On
The filling level of the pickup
position or dipping module is
low.
Respective side White: 100 -200
Green: --
Red: Off
Yellow: On
Green: On
Unable to move one of the
boards to the next area.
Respective side White: On
Green: --
Red: Off
Yellow: 500 - 500
Green: Off
Unable to read the board bar-
code in the input conveyor. The
operator must insert the board
manually.
Respective side Not configured Red: Off
Yellow: 500 - 500
Green: Off
The machine has been auto-
matically stopped due to a non-
configured event e.g. conveyor
error
. Events which have not been
configured and which could
lead to a machine stop have not
be taken into consideration
here.
Both sides White: On
Green: Off
Red: Off
Yellow: 500 - 500
Green: Off
The production has been auto-
matically stopped (e.g. there is
no component ready for pick-
up).
Respective side White: On
Green: Off
Red: Off
Yellow: 500 - 500
Green: Off
The machine is performing a
manual function triggered by
the operator.
White: 100 -1000
Green: 700 - 700
Red: Off
Yellow: Off
Green: 500 - 500
The machine has been stopped
due to a fiducial measurement
error ( z. B. board, table, feeder
module).
Both sides White: On
Green: Off
Red: Off
Yellow: 500 - 500
Green: Off
The safety loop has not closed. Respective side White: On
Green: Off
Red: On
Yellow: Off
Green: Off
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
User manual SIPLACE SX1/SX2 5 Working with the machine
From software version SC 706.1 SP1 Version 10/2014 5.7 Indicator lamps with horn
251
5.7.2.1 Basics
5
5.7.2.2 Frequency of flashes
5
5
5.7.2.3 Priorities
5
5.7.2.4 Reaction time
Each change to the machine status is shown at the indicator lamps within three seconds.
Status Meaning
Off No warning and no alert
Flashes Warning, the frequency varies depend on the type of warning on/
off in milliseconds.
On Alert
-- The described state does not affect the lamp concerned.
Normal flashing Green indicator lamp: 700 ms off, 700 ms on
White indicator lamp: 500 ms off, 500 ms on
Short flashing 100 ms off, 1000 ms on
Fast flashing 100 ms off, 200 ms on
Type of warning Priority
Definition for fast flashing Top
Definition for normal flashing Medium
Definition for short flashing Lowest