8.1.8 Pallet Detection Sensor 1. Press [SET] → [MANUAL] → [I/O] → [STANDARD I/O] → [OUTPUT] and turn on Y04A P.IN PLT FWD to move the pallet from the return conveyor stopper to the IN- pallet loader. 2. The pallet detect…

10. Adjust the stopper so the jaw is parallel to the bracket at the backward
end of the cylinder.
8.1.7 Pallet Shift Forward and Backward End Sensors
1. Turn on Y04A P.IN PLT FWD to advance the shift.
2. Find the position where the sensor turns on and off.
3. Move the sensor 1 mm to the ON direction.
4. Turn on Y04B P.IN PLT BWD and adjust the sensor position.
5. Use I/O to move the pallet from the return conveyor stopper to the IN-
pallet loader.
6. The pallet detection sensor lies diagonally across the pallet. There is no
sensitivity volume and it is not possible to adjust vertically. Adjust the
sensor angle by the mounting bolts. Move the pallet manually and check
the sensor reaction.
QP132T8004
Cylinder backward end
Stopper
Set to
parallel.
Chapter 8 8.1 In Shifter Adjustment
Edition 1.1 8-7 QP-132 Level 3 Tutorial

8.1.8 Pallet Detection Sensor
1. Press [SET] → [MANUAL] → [I/O] → [STANDARD I/O] → [OUTPUT]
and turn on Y04A P.IN PLT FWD to move the pallet from the return
conveyor stopper to the IN- pallet loader.
2. The pallet detection sensor lies diagonally across the pallet. There is no
sensitivity volume and it is not possible to adjust vertically. Adjust the
sensor angle by the mounting bolts. Move the pallet manually and check
the sensor reaction.
Chapter 8 8.1 In Shifter Adjustment
Edition 1.1 8-8 QP-132 Level 3 Tutorial

8.2 Training Evaluation
Circle the most appropriate answer from the list below.
(1) To adjust pallet 10 mm shift:
a. a block jig is required.
b. a dial gauge is required.
c. Both a and b above.
(2) To adjust pallet pass through check sensor:
a. advance the 10 mm shift.
b. place a pallet against the stopper.
c. Both a and b above.
(3) To adjust the sensitivy of pallet arrival check sensor:
a. a jig is used.
b. a pallet is used.
c. Both a and b above.
(4) To adjust pallet shift, set the 10 mm shift to:
a. the forward position.
b. the retract position.
c. The position does not matter.
(5) Pallet Shift Forward and Backward End Sensor sensitivity is adjusted by:
a. the amp.
b. the position of the sensor.
c. the angle of the sensor.
Chapter 8 8.2 Training Evaluation
Edition 1.0 8-9 QP-132 Level 3 Tutorial