Chapter 2
Out Manipulator

2.1 Replacing PO-Axis Motor
• Resolution : 0.025 mm/pulse
• Pulse per rotation : 800 pulse
• MY_reduce (deceleration distance) : 400 pulse
Zero set sensor position: 20 mm (800 pulse) from minus side
mechanical stopper.
Zero set complete position: 10 mm (400 pulse) from minus side
mechanical stopper.
1. Replace the motor and ensure that the coupling is tightened and
centered.
2. Hold down the axis change key [3] and [Reset] key then press [Power
On] to boot the machine in mechanical check mode.
3. Press the EMERGENCY STOP button to shutdown the 200V.
4. Push the PO-robot against the minus side mechanical stopper and check
the zero set sensor and dog.
5. Move the zero set dog to the right end of the oval-shaped hole so the
zero set sensor turns ON away from the mechanical stopper.
6. Move the PO-robot to the center of the stroke.
7. Press [INCH] → [Next data] or [Prev data] to select the MX-axis.
8. Press [SERVO ON] → [Start] to Servo ON and zero set.
-MS
3.5 mm (140 pulses)
Soft limit Soft limit
3.5 mm (140 pulses)
QP132T2001
10 mm (400 pulses)10 mm (400 pulses)
20 mm (800 pulses)
Zero set complete pos.
Zero set sensor
Motor
+MS
Chapter 2 2.1 Replacing PO-Axis Motor
Edition 1.1 2-1 QP-132 Level 3 Tutorial

9. After completion of zero-setting, press the EMERGENCY STOP button
to turn OFF the 200V.
10. Loosen the coupling and push the PO-robot against the minus side
mechanical stopper.
11. Rotate the motor to set the counter value to -400 ± 40 pulse.
12. Tighten the coupling. Coupling Torque: 1.47 Nm (0.15 kgf/m)
13. Push the PO-robot against the minus side mechanical stopper and make
sure the servo counter value is -400 ± 40 pulse.
14. Rotate the motor to set the servo counter to 400 ± 40 pulse.
15. Adjust the dog position so the zero set sensor turns ON at this position.
16. Press [SERVO ON] → START to Servo ON and zero set.
17. After completion of zero set, press the EMERGENCY STOP button to
turn OFF the 200V.
18. Move the PO-robot to the position where zero set sensor turns on and
make sure the servo counter value is 400 ± 40 pulse.
Chapter 2 2.1 Replacing PO-Axis Motor
Edition 1.1 2-2 QP-132 Level 3 Tutorial