QP132三级参考手册.pdf.pdf - 第70页

Notes: Chapter 4 4.5 Measuring PM Proper Data and Adjustment Edition 1.1 4-14 QP-132 Level 3 T utorial

100%1 / 136
4.5.2 Program Origin
Note: Module style and mechanical stroke on the X-axis is different between the X No. 4 ~ 12
and No.13 and later. Same adjustment method is available for both types. However, the
values are different.
1. Press the EMERGENCY STOP button to shutdown the 200V.
2. Attach a nozzle jig (ACGPJ9021) to holder A.
3. Set the X0, Y0 calibration jig (ACGPJ9030) on the 8-inch pallet.
4. Ensure that the SS-axis is at the SS0 position and set the 8-inch pallet to
the module.
5. Press [SET] [MANUAL] [I/O] [STANDARD I/O] [OUTPUT]
and Y061 SS PLT UCLP to unclamp.
6. Press Y062 SS PIN ON to turn on the SS pin.
7. Position the pallet holder to the SS-rail cam follower.
8. Press Y060 SS PLT CLP to clamp the pallet.
9. Move the head manually to the position where the nozzle jig goes
smoothly into the hole of the X0,Y0 calibration jig.
10. Press [SET] [PROPER] ID No. [PM] [Select the module]
[FINISH] [X/Y] [X0/Y0] [SET] to enter the Proper data.
QP132T4009
Holder A
Nozzle jig
X0, Y0 calibration jig
8-inch pallet
SS-rail
Chapter 4 4.5 Measuring PM Proper Data and Adjustment
Edition 1.1 4-13 QP-132 Level 3 Tutorial
Notes:
Chapter 4 4.5 Measuring PM Proper Data and Adjustment
Edition 1.1 4-14 QP-132 Level 3 Tutorial
4.6 Training Evaluation
Circle the most appropriate answer from the list below.
(1) Which is the correct order for installing the Z-motor?
a. Zero set, attach to the machine.
b. Attach to the machine and zero set.
c. Attach to the machine and no zero set is required.
(2) Program Origin is the value of:
a. zero coordinates of the sequence.
b. nozzle center position.
c. camera center position.
(3) Which nozzle holder is used to measure Placement Height Z?
a. A
b. A and D
c. A, B, C and D
(4) To install X or Y-motor, boot up the machine in:
a. mechanical check mode.
b. normal mode.
c. QP132 special mode.
(5) Which method should be used to enable the module?
a. Proper data setting
b. Command
c. Both a and b.
Chapter 4 4.6 Training Evaluation
Edition 1.0 4-15 QP-132 Level 3 Tutorial