QP132三级参考手册.pdf.pdf - 第91页
6.3 T raining Evaluation Circle the most appropriate answer from the list below. (1) If the gray scale value of back light nozzle is out of range: a. replace the Nozzle and UV lamp. b. replace the Camera. c. Both a and b…

Notes:
Chapter 6
6.2 Measuring Parts Camera Proper Data and Adjustment
Edition 1.1 6-10 QP-132 Level 3 Tutorial

6.3 Training Evaluation
Circle the most appropriate answer from the list below.
(1) If the gray scale value of back light nozzle is out of range:
a. replace the Nozzle and UV lamp.
b. replace the Camera.
c. Both a and b.
(2) To adjust Parts Camera, move the camera:
a up.
b. down.
c. Does not matter.
(3) To focus the parts camera:
a. the lowest positioned nozzle is used.
b. the highest positioned nozzle is used.
c. the average positioned nozzle is used.
(4) If parts camera resolution is too high:
a. raise the camera.
b. lower the camera.
c. lower the nozzle holder.
(5) Proper data nozzle offset is:
a. the distance of nozzle B, C, D from A
b. the distance between nozzle A, B, C and D
c the distance of nozzle B, C, D from Q-axis
Chapter 6 6.3 Training Evaluation
Edition 1.0 6-11 QP-132 Level 3 Tutorial

Notes:
Chapter 6 6.3 Training Evaluation
Edition 1.0 6-12 QP-132 Level 3 Tutorial