Section 1
Troubleshooting
0005-002 1-1 Tg0248-PM-ER
WARNING
In principle, the machine should be operated
by only one person for troubleshooting.
If there are more than one, ensure good com-
munication by giving loud verbal instructions.
Troubleshoot the machine carefully, protect-
ing your hands from moving mechanisms
when the machine is powered up.
When the [OPERATION/SET UP] switch is
set to the "SET UP" side, it becomes pos-
sible to operate the machine with the main-
tenance cover open. Be sure to pay a spe-
cial caution while operating the machine.
1. Cause and Remedy of Simple Trouble
0005-002 1-2 Tg0248-PM-ER
Table 1.1
1. Cause and Remedy of Simple Trouble
Trouble Cause Remedy
The power breaker crank
is kept OFF (
{
).
Set the power breaker crank to “ON” ( ).
Power is not supplied to
the connection terminal of
the primary power supply
unit.
Supply power to the connection terminal
of the primary power supply unit.
Although the [POWER
ON] button on the
operation panel is pressed,
power is not supplied.
Adequate air pressure is
not set.
Check the air pressure.
Main Pressure:
0.49 MPa (5 kgf/cm
2
)
Air Blowing Pressure:
0.015 MPa (0.15 kgf/cm
2
)
Pressure Switch:
0.39 MPa (4 kgf/cm
2
)
The air source cock is
closed.
Open the air source cock.
The main pressure is 0
(zero)”.
Air does not reach the air
source cock.
Check the air hose, etc.
Power is not supplied. Power up the machine as follows.
Set the power breaker crank to “ON” ( ).
Press and hold the [POWER ON] button
on the operation panel for more than 1
second.
Nothing is displayed on the
touch screen.
The screen saver function
is activated.
Touch the screen.
The operation panel and
the touch screen are un-
available for operation.
Operation availability is
locked on the opposite
side.
(The operation lock
(HD06) lamp is ON.)
Press the [PNL CHANGE] button on the
opposite side and press the same button on
the other side (on the panel to be oper-
ated).
Vacuum Pressure System
Check whether the vacuum pressure is correctly adjusted. *1
Set the operation mode to “PLACE” by pressing the [PASS/PLACE
CHANGE] key at the “AUTO OPN. SUB-MENU” display and turn
off all vacuum valves ([LA1-AXIS VACUUM/VACUUM BLOW],
[LA2-AXIS VACUUM/VACUUM BLOW], [LB1-AXIS VACUUM/
VACUUM BLOW], and [LB2-AXIS VACUUM/VACUUM BLOW]
Keys).
Confirm that “OFF” is set in the “STATUS” text boxes at the
“MANUAL SUBSYSTEM OPERATION” display.
Confirm that the vacuum pressure is -93 kPa (70 cmHg) or more
(Vacuum valve fully closed).
When the vacuum pressure is too low, it is required to replace the
vacuum pump with a new one.
Consult our sales personnel for the detailed information on how to
replace or repair the vacuum pump.
Check whether the vacuum pump is producing any abnormal sound. *2
Catch the sound of the vacuum pump and confirm that the sound is
not abnormal.
When abnormal sound is produced, consult our sales personnel for
the countermeasures.
Check whether the filter of the vacuum pump is stained or clogged.
*3
Refer to “Vacuum Pressure System” in “8. Maintenance (Every 3
Months) of Section 1 in Volume 4” and inspect the filter.
1.1 Confirmation and Countermeasures against Low
Component Pick-Up Rate
1.1.1 Confirmation of Low Component Pick-Up Rate (Handling
Errors)
Before confirming each item, check the following management information
and grasp the contents, the frequency, and the trend of pick-up errors.
(1) Machine Performance Data and Component Pick-Up/Placement In-
formation in Management Data
(2) Nozzle Management Data in Management Data
(3) Head Management Data in Management Data
(4) Handling Error per Feeder Location in Pattern Program Management
Data
(5) Recall Handling Error
(6) Recall Component Recognition Error
Refer to “4. RECALL MESSAGES of Section 3 in Volume 4” for the de-
tailed information on (1) through (4).
Refer to “3. MANAGEMENT DATA Display of Section 3 in Volume 4”
for the detailed information on (5) and (6).
1.1.2 Countermeasures against Frequent Pick-Up Errors
*1
*3
*2
0005-002 1-3 Tg0248-PM-ER
1. Cause and Remedy of Simple Trouble