3OM-1064-001.pdf - 第116页

(Cause 1) Is the original position deviated? (Reset Procedure in the case of Cause 1) Reset Procedure (1) Re-adjust the original position. (2) Press the [CLEAR ALARM] key and the buzzer stops sounding. (3) Press the [ZER…

100%1 / 308
Error Code Display A Display B
0005-002 2-72 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0C 04 04 ZB2-AXIS COMMUNICATION TIME-OUT OCCURRED IN RECEIVING REPLY FROM
STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 04 03 ZB2-AXIS COMMUNICATION COMMUNICATION ERROR WAS DETECTED BY
STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) Is the original position deviated?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Re-adjust the original position.
(2) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
3. Trouble Shooting after Error Display
0005-002 2-73 Tg0248-PM-ER
0D 01 04 BPC-AXIS ORIGIN ENCODER ORIGIN WAS DETECTED AT POINT OUT
OF ORIGIN (SLIDE).
0D 01 03 BPC-AXIS ORIGIN ORIGIN SENSOR (SLIDE) AND / OR LIMIT SENSOR
() MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0D 01 02 BPC-AXIS ORIGIN ORIGIN (SLIDE) WAS NOT DETECTED.
;BPH163 E / R
(Cause 1) The sensor may be defective.
(Cause 2) The cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel because a sensor or sensor
cable replacement might be required.
0D 01 01 BPC-AXIS ORIGIN ENCODER ORIGIN WAS NOT DETECTED.
(Cause 1) Motor encoder section may be defective.
(Cause 2) Encoder cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Turn off the power and check for loose connections between the sections of the motor and
signal cable.
(2) Re-start.
(3) If the device can’t be reset even after the above check, contact our service personnel because
the signal cable may be broken or the motor defective.
0D 01 05 BPC-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
ZEROING IS REQUIRED.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0005-002 2-74 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0D 01 06 BPC-AXIS ORIGIN THE AXIS WAS NOT AT ORIGIN.
0D 01 10 BPC-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0D 01 11 BPC-AXIS ORIGIN
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
LIMIT SENSOR (+)/() MIGHT BE DEFECTIVE.
0D 03 01 BPC-AXIS DATA TARGET LOCATION VALUE IS OUT OF RANGE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.