3OM-1064-001.pdf - 第271页

0103-001 4-54-4 Tg0248-PM-ER 5. Component Recognition Error Code and List of Error Messages Error Code Display A Display B 20672094 COMPONENT DETECTION ERROR NOZZLE PROTRUSION OCCUPIES COMPONENT OUTW ARD LENGTH. 20672101…

100%1 / 308
0103-001 4-54-3 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672085 COMPONENT DETECTION
ERROR
COMPONENT OUTWARD LENGTH Y WAS OUT OF
TOLERANCE.
20672084 COMPONENT DETECTION
ERROR
COMPONENT OUTWARD LENGTH X WAS OUT OF
TOLERANCE.
20672090 COMPONENT DETECTION
ERROR
RECOGNTION ABORTED BECAUSE OF IMPROPER
COMPONENT HANDLING.
20672086 COMPONENT DETECTION
ERROR
COMPONENT OUTLINE NOT FOUND.
(Cause 1) An improper parameter is set in the "X" or "Y" data box of the label "MOLD SIZE".
(Cause 2) Too small parameters are set in the "X" and "Y" data boxes of the label "MOLD SIZE
TOLERANCE".
The parameters set in the "X" and "Y" data boxes of the "MOLD SIZE TOLERANCE"
become valid when "MANUAL" is set in the "RECOG DATA SET" and "MOLD SIZE
TOLERANCE SET" data boxes.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The lighting is not ON.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
0103-001 4-54-4 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672094 COMPONENT DETECTION
ERROR
NOZZLE PROTRUSION OCCUPIES COMPONENT
OUTWARD LENGTH.
20672101 COMPONENT DETECTION
ERROR
CONTRAST BETWEEN COMPONENT AND BACK-
GROUND IS TOO LOW.
20672102 COMPONENT DETECTION
ERROR
THE DETECTED LEAD POSITION DOES NOT MATCH
THE POSITION DATA.
(Cause 1) The diameter of the selected nozzle is larger than the outline of the component.
(Cause 2) Improper parameters are set in the "X" and "Y" data boxes of the label "NOZZLE
OUTER SIZE" at the "NOZZLE TYPE DATA" display.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The lighting is not ON.
(Cause 2) The camera shutter speed is not suitable.
(In normal cases, the speed should be "5.0 to 11.0 ms".)
(Cause 3) The gain and level of the camera are not suitable.
(In normal cases, the gain should be "160 to 190" and the level "0 to 10".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The component library data is not suitable.
(The data can be checked through component recognition test.)
(Cause 2) The component thickness is not suitable.
(This error may occur because the entire image (the image captured by the camera) of
the component is large or small.)
(Cause 3) The camera magnification is not suitable.
(When four cameras are individually used to perform component recognition tests on
the component and this type of error occurs in only one camera, the camera magnifica-
tion may be wrong.)
(NEXT PAGE)
0103-001 4-54-5 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672103 COMPONENT DETECTION
ERROR
UNSPECIFIED LEADS ARE DETECTED.
20672104 COMPONENT DETECTION
ERROR
SOME LEADS CANNOT BE DETECTED.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The number of leads is not suitable.
(Cause 2) Objects shaped identically to the leads exist at both ends of the lead group.
(Cause 3) Dirt and dust have accumulated at both ends of the lead group.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The number of leads is not suitable.
(Cause 2) The lead width is not suitable.
(Too large or small parameter is set in the "WIDTH" data box of the label "LEAD
DATA".)
(Cause 3) The leads look blurred.
(There is an extremely dark lead compared with other leads.)
(Cause 4) The direction of the component feed (direction of the component) is not suitable.
(Cause 5) Dirt, etc., have adhered to the cover glass in the fixed lighting unit.
(This can be checked through the recognition monitor.)
(Reset Procedure in the case of Causes 1, 2, 3, 4 and 5)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.