60 03 01 BEAM-B POWER SHUT-OFF CIRCUIT PROTECT OR FOR BEAM-B SYSTEM W AS ACTIV A TED. (Cause 1) This is the device’ s self-diagnostic message. (Reset Procedure in the case of Cause 1) Reset Procedure (1) Press the [CLEAR…

100%1 / 308
Error Code Display A Display B
0005-002 2-84 Tg0248-PM-ER
3. Trouble Shooting after Error Display
60 02 03 BEAM-A POWER SHUT-OFF FEEDER COVER (A) WAS OPENED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
60 02 02 BEAM-A POWER SHUT-OFF SAFETY BAR (A) WAS OPENED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
60 02 01 BEAM-A POWER SHUT-OFF CIRCUIT PROTECTOR FOR BEAM-A SYSTEM IS
ACTIVATED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check the condition of following CB’s.
CB (Q301A) for YA-axis servo main circuit.
CB (Q302A) for XA-axis servo main circuit.
CB (Q303A) for LA1-axis servo main circuit.
CB (Q304A) for LA2-axis servo main circuit.
CB (Q311A) for servo control power supply.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can't be re-started, contact our service personnel.
60 03 01 BEAM-B POWER SHUT-OFF CIRCUIT PROTECTOR FOR BEAM-B SYSTEM WAS
ACTIVATED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check the condition of following CB’s.
CB (Q301B) for YB-axis servo main circuit.
CB (Q302B) for XB-axis servo main circuit.
CB (Q303B) for LB1-axis servo main circuit.
CB (Q304B) for LB-2-axis servo main circuit.
CB (Q311B) for servo control power supply.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-85 Tg0248-PM-ER
3. Trouble Shooting after Error Display
Error Code Display A Display B
0005-002 2-86 Tg0248-PM-ER
3. Trouble Shooting after Error Display
60 04 01 INTERLOCK UNLOCK OF BEAM-A STOPPER WAS DETECTED.
(Cause 1) Is the YA-axis stationary position stopper return limit (BPH029) sensor motion correct?
(Check it at “Input Check Display: INTERLOCK”)
This input is performed through a relay. Therefore, check also the relay motion
(K122A).
(Cause 2) Is there any dust etc. on the YA-axis stationary position stopper return limit (BPH029)
sensor which monitors the beam A mechanical stopper stationary position?
If so, completely remove it.
(Cause 3) Did you push the beam A intentionally by hand when the beam mechanical stopper was
inserted and the main power circuit shut off?
If the YA-axis slide origin is out of place, this error occurs.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
60 03 03 BEAM-B POWER SHUT-OFF FEEDER COVER (B) WAS OPENED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
60 03 02 BEAM-B POWER SHUT-OFF SAFETY BAR (B) WAS OPENED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.