3OM-1064-001.pdf - 第122页

(Cause 1) This is the device's self-diagnostic message. (Reset Procedure in the case of Cause 1) Reset Procedure (1) Press the [CLEAR ALARM] key and the buzzer stops sounding. (2) Press the [ZERO] button to return a…

100%1 / 308
Error Code Display A Display B
0005-002 2-78 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0D 06 04 BPC-AXIS INTERLOCK P.C.B. LOCATION NOT COMPLETED WITHIN SPECI-
FIED TIME.
(Cause 1) Is a correct value set for the width data of a product P.C.B.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check if P.C.B. size T is good for the P.C.B..
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
0D 06 03 BPC-AXIS INTERLOCK AN ERROR DETECTED IN CONTROL BOARD.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check the control jamper wires and wiring.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
0D 06 02 BPC-AXIS INTERLOCK “MOTOR RUNNING” SIGNAL DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check the setting of servodrivers and signal lines.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
0D 06 01 BPC-AXIS INTERLOCK L-AXIS NOT AT ORIGIN.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Zero L-axis.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0E 01 10 PWC-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
Error Code Display A Display B
3. Trouble Shooting after Error Display
0005-002 2-79 Tg0248-PM-ER
0E 01 02 PWC-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS. ZEROING IS
REQUIRED.
(Cause 1) Is the optical beam of limit sensor kept in the “E/NR” condition?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(3) Remove the cause which keeps the optical beam of the limit sensor in the “E/NR” condition.
(4) Press the [ZERO] button to return all the axes to their original positions.
(5) Re-start.
(6) If the device can’t be re-started, contact our service personnel.
0E 01 03 PWC-AXIS ORIGIN THE AXIS WAS NOT AT ORIGIN.
0E 01 01 PWC-AXIS ORIGIN EXCITATION-MONITOR SIGNAL FROM STEPPING
MOTOR DRIVER WAS NOT DETECTED.
(Cause 1) This error occurs when the optical beam of the sensor is always kept in the “E / NR” or
the “E / R” condition during zeroing operation.
(E / NR: Light Emitted and Not Received, E / R: Light Emitted and Received)
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Check whether the optical beam is always E / NR or E / R because of dirt on the sensor, or
whether the sensor is defective. How to check is to shine the optical beam of the sensor on a
piece of paper and check whether it is E / R or E / NR.
(3) Re-start.
(4) If the device still can’t be reset after the above procedures, contact our service personnel
because the sensor cable or sensor may be defective.
Error Code Display A Display B
0005-002 2-80 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0E 06 01 PWC-AXIS INTERLOCK L-AXIS NOT AT ORIGIN.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Zero L-axis.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0E 04 01 PWC-AXIS LIMIT LIMIT ERROR (+) IS DETECTED.;BPH151 E / NR
0E 04 02 PWC-AXIS LIMIT LIMIT ERROR () IS DETECTED.;BPH153 E / NR
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0E 03 01 PWC-AXIS DATA TARGET LOCATION VALUE IS OUT OF RANGE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0E 01 11 PWC-AXIS ORIGIN LIMIT SENSOR (+)/() MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.