Error Code Display A Display B 0005-002 2-86 Tg0248-PM-ER 3. T rouble Shooting after Error Display 60 04 01 INTERLOCK UNLOCK OF BEAM-A ST OPPER W AS DETECTED. (Cause 1) Is the Y A-axis stationary position stopper return …

60 03 01 BEAM-B POWER SHUT-OFF CIRCUIT PROTECTOR FOR BEAM-B SYSTEM WAS
ACTIVATED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check the condition of following CB’s.
• CB (Q301B) for YB-axis servo main circuit.
• CB (Q302B) for XB-axis servo main circuit.
• CB (Q303B) for LB1-axis servo main circuit.
• CB (Q304B) for LB-2-axis servo main circuit.
• CB (Q311B) for servo control power supply.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-85 Tg0248-PM-ER
3. Trouble Shooting after Error Display

Error Code Display A Display B
0005-002 2-86 Tg0248-PM-ER
3. Trouble Shooting after Error Display
60 04 01 INTERLOCK UNLOCK OF BEAM-A STOPPER WAS DETECTED.
(Cause 1) Is the YA-axis stationary position stopper return limit (BPH029) sensor motion correct?
(Check it at “Input Check Display: INTERLOCK”)
This input is performed through a relay. Therefore, check also the relay motion
(K122A).
(Cause 2) Is there any dust etc. on the YA-axis stationary position stopper return limit (BPH029)
sensor which monitors the beam A mechanical stopper stationary position?
If so, completely remove it.
(Cause 3) Did you push the beam A intentionally by hand when the beam mechanical stopper was
inserted and the main power circuit shut off?
If the YA-axis slide origin is out of place, this error occurs.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
60 03 03 BEAM-B POWER SHUT-OFF FEEDER COVER (B) WAS OPENED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
60 03 02 BEAM-B POWER SHUT-OFF SAFETY BAR (B) WAS OPENED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

Error Code Display A Display B
0005-002 2-87 Tg0248-PM-ER
3. Trouble Shooting after Error Display
60 04 04 INTERLOCK FEEDER WAS NOT SEATED PROPERLY AT BEAM-B
SIDE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Lifted feeder detection B1 (BPH055) ON (E / R (light emitted and received)).
Lifted feeder detection B2 (BPH056) OFF (E / NR (light emitted and not received)).
Check the condition of feeder installation.
If necessary, re-install correctly.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
60 04 03 INTERLOCK FEEDER WAS NOT SEATED PROPERLY AT BEAM-A
SIDE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Lifted feeder detection A1 (BPH053) ON (E / R (light emitted and received)).
Lifted feeder detection A2 (BPH054) OFF (E / NR (light emitted and not received)).
Check the condition of feeder installation.
If necessary, re-install correctly.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
60 04 02 INTERLOCK UNLOCK OF BEAM-B STOPPER WAS DETECTED.
(Cause 1) Is the YB-axis stationary position stopper return limit (BPH031) sensor motion correct?
(Check it at “Input Check Display: INTERLOCK”)
This input is performed through a relay. Therefore, check also the relay motion (K122B).
(The machine equipped with the relay board is (K32))
(Cause 2) Is there any dust etc. on the YB-axis stationary position stopper return limit (BPH031)
sensor which monitors the beam B mechanical stopper stationary position?
If so, completely remove it.
(Cause 3) Did you push the beam B intentionally by hand when the beam mechanical stopper was
inserted and the main power circuit shut off?
If the YB-axis slide origin is out of place, this error occurs.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.