3OM-1064-001.pdf - 第273页
0103-001 4-54-6 Tg0248-PM-ER 5. Component Recognition Error Code and List of Error Messages Error Code Display A Display B 20672105 COMPONENT DETECTION ERROR LEAD POSITION (LEAD LENGTH DIRECTION) W AS OUT OF TOLERANCE. •…

0103-001 4-54-5 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672103 COMPONENT DETECTION
ERROR
UNSPECIFIED LEADS ARE DETECTED.
20672104 COMPONENT DETECTION
ERROR
SOME LEADS CANNOT BE DETECTED.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The number of leads is not suitable.
(Cause 2) Objects shaped identically to the leads exist at both ends of the lead group.
(Cause 3) Dirt and dust have accumulated at both ends of the lead group.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The number of leads is not suitable.
(Cause 2) The lead width is not suitable.
(Too large or small parameter is set in the "WIDTH" data box of the label "LEAD
DATA".)
(Cause 3) The leads look blurred.
(There is an extremely dark lead compared with other leads.)
(Cause 4) The direction of the component feed (direction of the component) is not suitable.
(Cause 5) Dirt, etc., have adhered to the cover glass in the fixed lighting unit.
(This can be checked through the recognition monitor.)
(Reset Procedure in the case of Causes 1, 2, 3, 4 and 5)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.

0103-001 4-54-6 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672105 COMPONENT DETECTION
ERROR
LEAD POSITION (LEAD LENGTH DIRECTION) WAS
OUT OF TOLERANCE.
• This error occurs when "MANUAL" is set in the "RECOG DATA SET" data box, "ENBL
(AUTO)" or "ENBL (MNL)" in the "LEAD POS (LONG DIR) DETN" data box, and the
longitudinal direction of the lead exceeds its tolerance.
• This error occurs when "MANUAL" is set in the "RECOG DATA SET" data box, "ENBL
(AUTO)" or "ENBL (MNL)" in the "OUTWARD LENGTH DETN" data box, and the lead
position (longitudinal direction) close to the both ends of lead group exceeds its tolerance.
When "ENBL (AUTO)" is set in the "OUTWARD LENGTH DETN" data box, the tolerance is
automatically set.
(Cause 1) When "ENBL (AUTO)" is set in the "LEAD POS (LONG DIR) DETN" data box, the
tolerance is automatically set.
(Cause 2) The lead end is longer than the component data or a shorter lead exists.
(Cause 3) The leads look blurred.
(There is an extremely dark lead compared with other leads.)
(Cause 4) The lead end is longer than the component data or a shorter lead exists.
(Cause 5) The leads look blurred.
(There is an extremely dark lead compared with other leads.)
(Reset Procedure in the case of Causes 1, 2, 3, 4 and 5)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.

0103-001 4-54-7 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672106 COMPONENT DETECTION
ERROR
LEAD POSITION (LEAD ARRAY DIRECTION) WAS
OUT OF TOLERANCE.
20672122 COMPONENT DETECTION
ERROR
CONTRAST BETWEEN COMPONENT AND BACK-
GROUND IS TOO LOW.
When "AUTO" is set in the "RECOG DATA SET" data box, in the "RECOG DATA" data box +
"ENBL (AUTO)" in the "LEAD POS (LATL DIR) DETN" data box, tolerance is automatically set.
This error can be avoided by setting in the "RECOG DATA" data box + in the "RECOG DATA
SET" data box and "DISABLE" in the "LEAD POS (LATL DIR) DETN" data box.
When these parameters are set, no bent lead is detected.
(Cause 1) There is a bent lead.
(Cause 2) The lead width is not suitable.
(When the lead width tolerance is automatically set and a parameter smaller than the
actual width is set as the lead width, a smaller parameter (tolerance decreased as much
as the reduction of the lead width) is also set.)
(Cause 3) The component thickness and the camera magnification are not suitable.
(When an image larger or smaller than the actual component size (component data) is
captured, the closer to both ends of the lead group the leads are located, the greater the
positional deviation becomes and such leads
are detected as "bent ones".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to
their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
Actual Component
Component Data
(Cause 1) The lighting is not ON.
(Cause 2) The camera shutter speed is not suitable.
(In normal cases, the speed should be "5.0 to 11.0 ms".)
(Cause 3) The gain and level of the camera are not suitable.
(In normal cases, the gain should be "160 to 190" and the level "0 to 10".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.