3OM-1064-001.pdf - 第125页
(Cause 1) This is the device’ s self-diagnostic message. (Reset Procedure in the case of Cause 1) Reset Procedure (1) Press the [CLEAR ALARM] key and the buzzer stops sounding. (2) Check the full/half setting of motor dr…

(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check the control jumper wires and wiring.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
0E 06 05 PWC-AXIS INTERLOCK NOT COMPLETED WITHIN SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-81 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0E 06 03 PWC-AXIS INTERLOCK BACKUP PLATE DETECTED. (BPH711) E / NR
(Cause 1) This is the device’s self-diagnostic message?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Remove B / P plate and perform zeroing operation.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
0E 06 04 PWC-AXIS INTERLOCK AN ERROR DETECTED IN CONTROL BOARD.
0E 06 02 PWC-AXIS INTERLOCK BACKUP PIN DETECTED. (BPH149) E / NR
(Cause 1) Does the support pin keep the sensor (BPH149) in the “E/NR” condition?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Install the support pin to the specified position.
(3) Zero PWC-axis.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.

(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check the full/half setting of motor driver (AMPD201).
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
20 01 04 TFA1-AXIS ORIGIN TAPE FEED MOVEMENT NOT COMPLETED WITHIN
SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Please confirm a sandwiched what for a feeder base/tape feeder lever.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0009-001 2-81-1 Tg0248-PM-ER
20 01 02 TFA1-AXIS ORIGIN ORIGIN OFF-EDGE NOT DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check proximity origin sensor (BPH201) and TFA1-AXIS dog.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
20 01 03 TFA1-AXIS ORIGIN ORIGIN NOT DETECTED AFTER ZEROING.
20 01 01 TFA1-AXIS ORIGIN ORIGIN ON-EDGE NOT DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check proximity origin sensor (BPH201) and TFA1-AXIS dog.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
3. Trouble Shooting after Error Display

3. Trouble Shooting after Error Display
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
20 02 04 TFA1-AXIS TIMING TAPE FEED MOVEMENT NOT COMPLETED WITHIN
SPECIFIED TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Please confirm a sandwiched what for a feeder base/tape feeder lever.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0009-001 2-81-2 Tg0248-PM-ER
20 02 02 TFA1-AXIS TIMING ORIGIN NOT DETECTED AFTER COMPLETION
OF MOVEMENT.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Loss of synchronism in motor may be caused. Check the tape feeder.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
20 02 03 TFA1-AXIS TIMING MACHINE NOT ACTIVATED DUE TO INCOMPLETE
PREVIOUS OPERATION.
20 02 01 TFA1-AXIS TIMING ZEROING OPERATION NOT COMPLETED.
MACHINE NOT ACTIVATED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Remove NG feeder and zero TFA1-AXIS.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.