3OM-1064-001.pdf - 第172页
0009-003 2-113 Tg0248-PM-ER Error Code Display A Display B 3. T rouble Shooting after Error Display 6C 01 0A ILLEGAL OPERA TION INTERLOCK BYP ASS SW W AS SWITCHED DURING MA- CHINE OPERA TION IN OPERA TION P ANEL LOCK ST …

6C 01 05 ILLEGAL OPERATION THE BPC-AXIS IS NOT AT LOCATE POSITION.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can't be re-started, contact our service personnel.
0005-002 2-112 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6C 01 04 ILLEGAL OPERATION OPERATION SW WAS SWITCHED DURING MACHINE
OPERATION.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Set the [OPERATION/SET UP] switch to the “OPERATION” mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can't be re-started, contact our service personnel.
6C 01 03 ILLEGAL OPERATION P.C.B. REMOVED FROM CONVEYOR.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Set the [OPERATION/SET UP] switch to the “OPERATION” mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can't be re-started, contact our service personnel.
6C 01 02 ILLEGAL OPERATION P.C.B. IS PUT ON THE CONVEYOR.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can't be re-started, contact our service personnel.

0009-003 2-113 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6C 01 0A ILLEGAL OPERATION
INTERLOCK BYPASS SW WAS SWITCHED DURING MA-
CHINE OPERATION IN OPERATION PANEL LOCK STATE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Switch interlock bypass to off position.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6C 01 09 ILLEGAL OPERATION INTERLOCK BYPASS SW WAS SWITCHED
DURING MACHINE OPERATION.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Switch interlock bypass to off position.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6C 01 08 ILLEGAL OPERATION OPERATION SW ON INACTIVE PANEL WAS
SWITCHED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Set the [OPERATION/SET UP] switch to the “OPERATION” mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6C 01 07 ILLEGAL OPERATION OPERATION SW WAS SWITCHED IN LOAD POWER
SHUT-OFF STATE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Set the [OPERATION/SET UP] switch to the “OPERATION” mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.

0009-001 2-113-1 Tg0248-PM-ER
Error Code Display A Display B
6C 01 0D ILLEGAL OPERATION
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
6C 01 0C ILLEGAL OPERATION
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
6C 01 0B ILLEGAL OPERATION
INTERLOCK BYPASS SW WAS SWITCHED DURING MA-
CHINE OPERATION IN LOAD POWER SHUT-OFF STATE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Switch interlock bypass to off position.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.