3OM-1064-001.pdf - 第9页

Section 1 T roubleshooting 0005-002 1-1 Tg0248-PM-ER

100%1 / 308
Check Items in Operation
0005-002 6 Tg0248-PM-ER
Check Items in Operation
WARNING
Before performing operation, turn off the power
and the air sources and lock the power breaker
using the padlock according to need.
Designate a personnel who can have charge of the padlock key.
If the provided padlock is lost or damaged, purchase its substitute.
Padlock
Main Valve
Power Breaker
Padlock
(No. 2500 30 MM)
Section 1
Troubleshooting
0005-002 1-1 Tg0248-PM-ER
WARNING
In principle, the machine should be operated
by only one person for troubleshooting.
If there are more than one, ensure good com-
munication by giving loud verbal instructions.
Troubleshoot the machine carefully, protect-
ing your hands from moving mechanisms
when the machine is powered up.
When the [OPERATION/SET UP] switch is
set to the "SET UP" side, it becomes pos-
sible to operate the machine with the main-
tenance cover open. Be sure to pay a spe-
cial caution while operating the machine.
1. Cause and Remedy of Simple Trouble
0005-002 1-2 Tg0248-PM-ER
Table 1.1
1. Cause and Remedy of Simple Trouble
Trouble Cause Remedy
The power breaker crank
is kept OFF (
{
).
Set the power breaker crank to “ON” ( ).
Power is not supplied to
the connection terminal of
the primary power supply
unit.
Supply power to the connection terminal
of the primary power supply unit.
Although the [POWER
ON] button on the
operation panel is pressed,
power is not supplied.
Adequate air pressure is
not set.
Check the air pressure.
Main Pressure:
0.49 MPa (5 kgf/cm
2
)
Air Blowing Pressure:
0.015 MPa (0.15 kgf/cm
2
)
Pressure Switch:
0.39 MPa (4 kgf/cm
2
)
The air source cock is
closed.
Open the air source cock.
The main pressure is 0
(zero)”.
Air does not reach the air
source cock.
Check the air hose, etc.
Power is not supplied. Power up the machine as follows.
Set the power breaker crank to “ON” ( ).
Press and hold the [POWER ON] button
on the operation panel for more than 1
second.
Nothing is displayed on the
touch screen.
The screen saver function
is activated.
Touch the screen.
The operation panel and
the touch screen are un-
available for operation.
Operation availability is
locked on the opposite
side.
(The operation lock
(HD06) lamp is ON.)
Press the [PNL CHANGE] button on the
opposite side and press the same button on
the other side (on the panel to be oper-
ated).