5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672196 COMPONENT DETECTION
ERROR
CONTRAST BETWEEN BALL AND BACKGROUND IS
TOO LOW.
20672197 COMPONENT DETECTION
ERROR
THE BALLS CANNOT BE DETECTED ADEQUATELY.
20672223 COMPONENT DETECTION
ERROR
CONTRAST BETWEEN BALL AND BACKGROUND IS
TOO LOW.
20672198 COMPONENT DETECTION
ERROR
THE BALLS CANNOT BE DETECTED ADEQUATELY.
(Cause 1) The lighting is not ON.
(Cause 2) The camera shutter speed is not suitable.
(In normal cases, the speed should be "5.0 to 11.0 ms".)
(Cause 3) The gain and level of the camera are not suitable.
(In normal cases, the gain should be "160 to 190" and the level "0 to 10".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The lighting is not ON.
(Cause 2) The camera shutter speed is not suitable.
(In normal cases, the speed should be "5.0 to .0 ms".)
(Cause 3) The gain and level of the camera are not suitable.
(In normal cases, the gain should be "160 to 190" and the level "0 to 10".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
0103-003 4-56 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672236 COMPONENT DETECTION
ERROR
SOME BALLS CANNOT BE DETECTED.
20672235 COMPONENT DETECTION
ERROR
UNSPECIFIED BALLS ARE DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) Wrong parameters are set in the "# OF ROWS" and "# OF COLS" data boxes of the
label "MISSING BALL DATA".
(The data can be checked through component recognition test.)
(Cause 2) A wrong parameter is set in the "BALL DIAMETER" data box.
(When the ball diameter differs greatly, a larger or a smaller ball among the detected
balls may be omitted as non-objective one.)
(Cause 3) The lighting is dark.
(Cause 4) Dirt, etc., have adhered to the cover glass in the fixed lighting unit.
(This can be checked through the recognition monitor.)
(Reset Procedure in the case of Causes 1, 2, 3 and 4)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Set "MANUAL (FRONT LTG)" in the "LTG MODE" data box to increase the brightness of
the lighting and perform the recognition. When the cause of this error lies apparently in the
lighting system and cannot be avoided even after the lighting is adjusted, set "MANUAL" in
the "RECOG DATA SET" data box and "2 (No Recognition on All Balls)" in the "RECOG
LEVEL" data box at the "CMPNT LIBRARY [RECOG]" display and then perform the
recognition.
The recognition is not implemented on all balls.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0103-001 4-56-1 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672237 COMPONENT DETECTION
ERROR
SOME UNDETECTABLE BALLS EXIST IN A ROW OR
A COLUMN OUTSIDE THE GROUP.
20672238 COMPONENT DETECTION
ERROR
AN UNDETECTABLE ROW OR COLUMN EXISTS
OUTSIDE THE GROUP.
20672239 COMPONENT DETECTION
ERROR
THE DETECTED BALL POSITION DOES NOT MATCH
THE POSITION DATA.
(Cause 1) The pick-up position and the angle are shifted greatly.
(When the pick-up position and the angle are shifted greatly, this error may occur
because the balls outside the group are excluded from the inspected position, disabling
the detection.)
(Cause 2) Wrong parameters are set in the "# OF ROWS" and "# OF COLS" data boxes of the
label "MISSING BALL DATA".
(This can be checked through component recognition test.)
(Cause 3) A wrong parameter is set in the "BALL DIAMETER" data box.
[When the ball diameter differs greatly, a larger (or a smaller) ball among the detected
balls may be omitted as non-objective one.]
(Cause 4) The lighting is dark.
(Cause 5) Dirt, etc., have adhered to the cover glass in the fixed lighting unit.
(This can be checked through the recognition monitor.)
(Reset Procedure in the case of Causes 1, 2, 3, 4 and 5)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Set "MANUAL (FRONT LTG)" in the "LTG MODE" data box to increase the brightness of
the lighting and perform the recognition. When the cause of this error lies apparently in the
lighting system and cannot be avoided even after the lighting is adjusted, set "MANUAL" in
the "RECOG DATA SET" data box and "2 (No Recognition on All Balls)" in the "RECOG
LEVEL" data box at the "CMPNT LIBRARY [RECOG]" display and then perform the
recognition.
The recognition is not implemented on all balls.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.