3OM-1064-001.pdf - 第254页
0103-003 4-51 Tg0248-PM-ER Error Code Display A Display B 5. Component Recognition Error Code and List of Error Messages 2043A140 ELECTRICAL CONT ACT to 149 (RIGHT) RECOGNITION ERROR Note : A represents “2” or “3”. CORNE…

Note: The second digit from the last one of the error code represents Electrical Contact 1, 2, or 3.
The third digit from the last one of the error code represents Electrical Contact Position 0,
1, 2, or 3.
0: Upper Side 1: Left Side 2: Lower Side 3: Right Side
(Cause 1) Wrong parameters (electrical contact data) are set in the component library data for the
selected component.
(Cause 2) Is there any inconsistent reflection at the electrical contact corner or edge?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Check the selected component and the electrical contact data in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
(Reset Procedure in the case of Cause 2)
Reset Procedure
(1) In this case, change the lighting mode to “MANUAL (FRONT LIGHTING)” and perform the
recognition with much brighter light.
EDGE (UPPER-RIGHT) OF ELECTRICAL CONTACT 3
IS UNABLE RECOGNITION.
0103-001 4-50-1 Tg0248-PM-ER
Error Code Display A Display B
5. Component Recognition Error Code and List of Error Messages
2042A330 ELECTRICAL CONTACT (LOW-
to 339 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-RIGHT) OF ELECTRICAL CON-
TACT 3 IS UNABLE RECOGNITION.
2042A320 ELECTRICAL CONTACT (LOW-
to 329 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-LEFT) OF ELECTRICAL CONTACT
3IS UNABLE RECOGNITION.
2042A370 ELECTRICAL CONTACT (LOW-
to 379 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (LOWER-LEFT) OF ELECTRICAL CONTACT 3
IS UNABLE RECOGNITION.
2042A380 ELECTRICAL CONTACT (LOW-
to 389 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (LOWER-RIGHT) OF ELECTRICAL CONTACT 3
IS UNABLE RECOGNITION.
2042A390 ELECTRICAL CONTACT (LOW-
to 399 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
2042A340 ELECTRICAL CONTACT (LOW-
to 349 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-RIGHT) OF ELECTRICAL CON-
TACT 3 IS UNABLE RECOGNITION.
2042A350 ELECTRICAL CONTACT (LOW-
to 359 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING EDGE
RECOGNITION OF ELECTRICAL CONTACT 3.
2042A360 ELECTRICAL CONTACT (LOW-
to 369 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-LEFT) OF ELECTRICAL CONTACT 3 IS
UNABLE RECOGNITION.

0103-003 4-51 Tg0248-PM-ER
Error Code Display A Display B
5. Component Recognition Error Code and List of Error Messages
2043A140 ELECTRICAL CONTACT
to 149 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-RIGHT) OF ELECTRICAL CON-
TACT 1 IS UNABLE RECOGNITION.
2043A150 ELECTRICAL CONTACT
to 159 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING EDGE
RECOGNITION OF ELECTRICAL CONTACT 1.
2043A010 ELECTRICAL CONTACT
to 049 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
NOZZLE PROTRUSION PRESENTS ON SOME ELEC-
TRICAL CONTACTS.
2043A170 ELECTRICAL CONTACT
to 179 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (LOWER-LEFT) OF ELECTRICAL CONTACT 1
IS UNABLE RECOGNITION.
2043A160 ELECTRICAL CONTACT
to 169 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-LEFT) OF ELECTRICAL CONTACT 1 IS
UNABLE RECOGNITION.
2043A100 ELECTRICAL CONTACT
to 109 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING CORNER
RECOGNITION OF ELECTRICAL CONTACT 1.
2043A110 ELECTRICAL CONTACT
to 119 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-LEFT) OF ELECTRICAL CONTACT
1 IS UNABLE RECOGNITION.
2043A120 ELECTRICAL CONTACT
to 129 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-LEFT) OF ELECTRICAL CONTACT
1 IS UNABLE RECOGNITION.
2043A130 ELECTRICAL CONTACT
to 139 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-RIGHT) OF ELECTRICAL CON-
TACT 1 IS UNABLE RECOGNITION.
INTERNAL ERROR OCCURRED DURING EDGE
RECOGNITION OF ELECTRICAL CONTACT 2.
EDGE (LOWER-RIGHT) OF ELECTRICAL CONTACT 1
IS UNABLE RECOGNITION.
2043A190 ELECTRICAL CONTACT
to 199 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-RIGHT) OF ELECTRICAL CONTACT 1
IS UNABLE RECOGNITION.
2043A200 ELECTRICAL CONTACT
to 209 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING CORNER
RECOGNITION OF ELECTRICAL CONTACT 2.
2043A220 ELECTRICAL CONTACT
to 229 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-LEFT) OF ELECTRICAL CONTACT
2 IS UNABLE RECOGNITION.
2043A230 ELECTRICAL CONTACT
to 239 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-RIGHT) OF ELECTRICAL CON-
TACT 2 IS UNABLE RECOGNITION.
2043A210 ELECTRICAL CONTACT
to 219 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-LEFT) OF ELECTRICAL CONTACT
2 IS UNABLE RECOGNITION.
2043A240 ELECTRICAL CONTACT
to 249 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-RIGHT) OF ELECTRICAL CON-
TACT 2 IS UNABLE RECOGNITION.
2043A180 ELECTRICAL CONTACT
to 189 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
2043A250 ELECTRICAL CONTACT
to 259 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
(NEXT PAGE)

Note: The second digit from the last one of the error code represents Electrical Contact 1, 2, or 3.
The third digit from the last one of the error code represents Electrical Contact Position 0,
1, 2, or 3.
0: Upper Side 1: Left Side 2: Lower Side 3: Right Side
(Cause 1) Wrong parameters (electrical contact data) are set in the component library data for the
selected component.
(Cause 2) Is there any inconsistent reflection at the electrical contact corner or edge?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Check the selected component and the electrical contact data in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
(Reset Procedure in the case of Cause 2)
Reset Procedure
(1) In this case, change the lighting mode to “MANUAL (FRONT LIGHTING)” and perform the
recognition with much brighter light.
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
0103-003 4-52 Tg0248-PM-ER
2043A300 ELECTRICAL CONTACT
to 309 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING CORNER
RECOGNITION OF ELECTRICAL CONTACT 3.
2043A310 ELECTRICAL CONTACT
to 319 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-LEFT) OF ELECTRICAL CONTACT
3 IS UNABLE RECOGNITION.
EDGE (UPPER-LEFT) OF ELECTRICAL CONTACT 2 IS
UNABLE RECOGNITION.
EDGE (LOWER-LEFT) OF ELECTRICAL CONTACT 2
IS UNABLE RECOGNITION.
EDGE (LOWER-RIGHT) OF ELECTRICAL CONTACT 2
IS UNABLE RECOGNITION.
EDGE (UPPER-RIGHT) OF ELECTRICAL CONTACT 2
IS UNABLE RECOGNITION.
2043A260 ELECTRICAL CONTACT
to 269 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
2043A270 ELECTRICAL CONTACT
to 279 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
2043A280 ELECTRICAL CONTACT
to 289 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.
2043A290 ELECTRICAL CONTACT
to 299 (RIGHT) RECOGNITION ERROR
Note: A represents “2” or “3”.